Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric PowerPact HDL36060

Product image is representative; revision or series may vary. Contact us to request a specific version.

HDL36060

|

The HDL36060 from Schneider Electric is a robust circuit breaker specifically designed to handle a line rated current of 60 A across three poles. Engineered for high performance, this circuit breaker supports a maximum breaking capacity of 25 kA and operational voltage of up to 690 VAC, making it suitable for demanding applications.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for HDL36060

ManufacturerSchneider Electric
Product TypeCircuit Breaker
Product LinePowerPact
Part NumberHDL36060
UPC785901577959
Weight4.00 lbs (1.81 kg)
Line Rated Current60 A
Number of Poles3
Control TypeToggle
Breaking Capacity CodeD
Maximum Breaking Capacity25 kA
Rated Operational Voltage690 VAC
Min. Operating Frequency50 Hz
Max. Operating Frequency60 Hz
Rated Impulse Withstand Voltage8 kV
Trip Unit TechnologyThermal Magnetic
Magnetic Tripping Current1450 A
Magnetic Hold Current800 A
Continuous Current Rating80%

The HDL36060 circuit breaker in the PowerPact series by Schneider Electric is built to provide reliable circuit protection for demanding scenarios. With an impressive line rated current of 60 A over three poles, it is engineered for functionality and efficiency. This model utilizes toggle control for simple operation and accessibility. The circuit breaker is designed to manage a rated operational voltage of up to 690 VAC, making it suitable for various high-voltage applications.

In terms of performance capabilities, the HDL36060 boasts a high breaking capacity of 25 kA, ensuring that it can effectively interrupt electrical faults. The device operates efficiently within a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. It features a rated impulse withstand voltage of 8 kV, offering additional protection against voltage surges.

Equipped with thermal magnetic trip unit technology, the HDL36060 enhances operational safety with a magnetic tripping current of 1450 A. It also incorporates an 800 A magnetic hold current, allowing the circuit breaker to maintain stability under normal operating conditions. Furthermore, it has a continuous current rating of 80%, which optimizes its use across various settings. The circuit breaker has a total weight of 2.2 kg, facilitating convenient installation and handling.