Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric PowerPact QDA222254

Product image is representative; revision or series may vary. Contact us to request a specific version.

QDA222254

|

The QDA222254 circuit breaker from Schneider Electric's PowerPact series is designed with a line rated current of 225 A across two poles. It features an operating handle for control and has a thermal-magnetic trip unit technology for reliable protection.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for QDA222254

ManufacturerSchneider Electric
Product TypeCircuit Breaker
Product LinePowerPact
Part NumberQDA222254
UPC785901988090
Weight5.00 lbs (2.27 kg)
Line Rated Current225 A
Number of Poles2
Control TypeOperating Handle
Breaking Capacity CodeD
Breaking Capacity25 kA
Rated Operational Voltage240 V
Minimum Operating Frequency50 Hz
Maximum Operating Frequency60 Hz
Rated Impulse Withstand Voltage8 kV
Trip Unit TechnologyThermal-Magnetic
Magnetic Tripping Current2400 A
Magnetic Hold Current1200 A
Continuous Current Rating80%
Mounting ModeI-Line Bracket

The Schneider Electric part number QDA222254 is an advanced circuit breaker within the PowerPact series. Constructed to maintain a line rated current of 225 A, it consists of two poles designed for optimal performance in load management. Control is facilitated via an operating handle, allowing for user-friendly engagement. The breaker exhibits a robust breaking capacity of 25 kA, ensuring it can interrupt significant fault currents effectively.

This circuit breaker operates under a rated operational voltage of 240 V, suitable for a wide range of electrical systems. It accommodates a frequency range from 50 Hz up to 60 Hz, which offers versatility for different use cases. The rated impulse withstand voltage is established at 8 kV, enhancing its reliability during voltage spikes.

The trip unit technology is thermal-magnetic, providing combined overcurrent protection. Magnetic tripping current is rated at 2400 A, and it can hold currents up to 1200 A without tripping, thereby ensuring a continuous current rating of 80%. For installation, it utilizes an I-Line bracket mounting mode, which simplifies the process in panel setups while ensuring secure placement. Overall, the QDA222254 circuit breaker is engineered for durability and safety in electrical applications.