Product image is representative; revision or series may vary. Contact us to request a specific version.
The Schneider Electric EJB34125 is a miniature circuit breaker noted for its reliable performance in various applications. It is equipped with a current rating of 125 A and operates at a voltage rating of 480Y/277 VAC, suitable for specific configurations in electrical systems.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Miniature circuit breaker |
| Product Line | Square D |
| Part Number | EJB34125 |
| Weight | 4.00 lbs (1.81 kg) |
| Trip Unit Rating | 2300 A |
| Voltage Rating | 480Y/277 VAC |
| Current Rating | 125 A |
| Number of Poles | 3 Poles |
| Breaking Capacity | 65 kA at 480Y/277 VAC; 100 kA at 240 VAC; 100 kA at 120/240 VAC |
| Trip Unit Technology | Thermal-magnetic |
| Mounting Mode | Bolt-on |
| Electrical Connection | Lugs, aluminium |
| Wire Range (AWG) | AWG 12-2/0 (Al) and AWG 14-2/0 (Cu) |
| Holding Current | 1000 A |
| Local Signalling | Trip indicator |
| Circuit Breaker Application | HACR rated |
| Product Destination | NF panelboard |
The EJB34125 model from Schneider Electric is a miniature circuit breaker designed to protect electrical systems efficiently. It is particularly effective for setups operating at 480Y/277 VAC, with a rated current of 125 A. The device boasts a substantial trip unit rating of 2300 A, making it very suitable for demanding applications. With three poles, it can adequately handle loads in various configurations.
This circuit breaker employs thermal-magnetic trip unit technology, ensuring reliable operation under fault conditions. It has a breaking capacity of 65 kA at 480Y/277 VAC and can withstand up to 100 kA for both 240 VAC and 120/240 VAC, providing safety in instances of overcurrent.
Weighing 4.0 lbs, the EJB34125 is bolted for mounting, ensuring stability in installation. The electrical connection utilizes lugs made of aluminum, accommodating a wire range from AWG 12 to 2/0 for aluminum wires and AWG 14 to 2/0 for copper wires. The device also supports a holding current of 1000 A.
Local indication of trip conditions is facilitated through a clear trip indicator, assisting in quick diagnostics. Additionally, the EJB34125 is HACR rated, making it suitable for heating, air conditioning, and refrigeration applications. This unit is intended for installation in NF panelboards, streamlining integration into existing setups.