HDA36070

|

The Schneider Electric HDA36070 is a reliable circuit breaker with a rated current of 70 A and three poles. Designed for stability and safety, it features thermal magnetic trip unit technology.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for HDA36070

ManufacturerSchneider Electric
Product TypeCircuit Breaker
Product LineSquare D
Part NumberHDA36070
UPC785901419976
Weight5.50 lbs (2.49 kg)
Line Rated Current70 A
Number of Poles3
Control TypeToggle
Breaking Capacity CodeD
Maximum Breaking Capacity25 kA
Rated Operational Voltage690 VAC
Minimum Operating Frequency50 Hz
Maximum Operating Frequency60 Hz
Rated Impulse Withstand Voltage8 kV
Trip Unit TechnologyThermal Magnetic
Magnetic Tripping Current1450 A
Magnetic Hold Current800 A
Continuous Current Rating80%
Mounting Height4.5 inches

The HDA36070 from Schneider Electric’s Square D series operates as a circuit breaker, featuring a robust construction designed to manage electrical loads efficiently. The device is rated for 70 A in-line current and features three poles for effective circuit segmentation. The control mechanism utilizes a toggle switch, allowing for straightforward operation.

Rated at a maximum breaking capacity of 25 kA, this breaker ensures reliable protection against potential overload or short circuits. The operational capability extends to 690 VAC while it supports a frequency range from 50 Hz to 60 Hz, making it adaptable to various systems. Additionally, it can withstand impulse voltages of 8 kV, reinforcing its resilience in demanding environments.

This model utilizes thermal magnetic trip unit technology, providing effective tripping characteristics. It further accommodates a magnetic tripping current of 1450 A, while the magnetic hold current is set at 800 A, providing enhanced protection during transient conditions. The continuous current rating is specified at 80%, ensuring optimal performance.

For convenient installation, the mounting height of the HDA36070 circuit breaker is set at 4.5 inches, allowing for seamless integration into standard electrical panels.