| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | Square D |
| Part Number | HDA36070 |
| UPC | 785901419976 |
| Weight | 5.50 lbs (2.49 kg) |
| Line Rated Current | 70 A |
| Number of Poles | 3 |
| Control Type | Toggle |
| Breaking Capacity Code | D |
| Maximum Breaking Capacity | 25 kA |
| Rated Operational Voltage | 690 VAC |
| Minimum Operating Frequency | 50 Hz |
| Maximum Operating Frequency | 60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Trip Unit Technology | Thermal Magnetic |
| Magnetic Tripping Current | 1450 A |
| Magnetic Hold Current | 800 A |
| Continuous Current Rating | 80% |
| Mounting Height | 4.5 inches |
The HDA36070 from Schneider Electric’s Square D series operates as a circuit breaker, featuring a robust construction designed to manage electrical loads efficiently. The device is rated for 70 A in-line current and features three poles for effective circuit segmentation. The control mechanism utilizes a toggle switch, allowing for straightforward operation.
Rated at a maximum breaking capacity of 25 kA, this breaker ensures reliable protection against potential overload or short circuits. The operational capability extends to 690 VAC while it supports a frequency range from 50 Hz to 60 Hz, making it adaptable to various systems. Additionally, it can withstand impulse voltages of 8 kV, reinforcing its resilience in demanding environments.
This model utilizes thermal magnetic trip unit technology, providing effective tripping characteristics. It further accommodates a magnetic tripping current of 1450 A, while the magnetic hold current is set at 800 A, providing enhanced protection during transient conditions. The continuous current rating is specified at 80%, ensuring optimal performance.
For convenient installation, the mounting height of the HDA36070 circuit breaker is set at 4.5 inches, allowing for seamless integration into standard electrical panels.