TSXPSY5500M

|

The TSXPSY5500M power supply module from Schneider Electric operates effectively in both 200-240 V AC and 100-120 V AC voltage ranges, proving versatile in power management applications. This module is built for a range of network frequencies, supporting operations at 50/60 Hz.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for TSXPSY5500M

ManufacturerSchneider Electric
Product LineTSX Micro PLCs
Part NumberTSXPSY5500M
EAN3389110725629
Weight1.00 lbs (0.45 kg)
Primary Voltage200-240 V AC (190-264 V) / 100-120 V AC (85-140 V)
Network Frequency50/60 Hz
Module TypePower Supply Module
Network Frequency Limits47-63 Hz
Input Current500 mA at 240 V / 1700 mA at 100 V
Operating Altitude0 to 2000 meters
Relative Humidity10 to 95% without condensation for operation, 5 to 95% without condensation for storage
Storage Temperature-25 to 70 °C
Operating Temperature0 to 60 °C
Local Signalling1 LED for battery fault (red), 1 LED for presence of voltages (green), 1 LED for presence of sensor voltage (green)
Inrush Current38 A at 240 V / 38 A at 100 V
Total Useful Secondary Power50 W
Secondary Power35 W at 5 V DC / 19 W at 24 V DC
Current at Secondary Voltage7 A at 5 V DC / 0.8 A at 24 V DC (sensor power supply) / 0.8 A at 24 V DC (relay power supply)
Protection TypeInternal fuse (4 A, 5 x 20 mm, time-delayed), overload protection, overvoltage protection, short-circuit protection

The Schneider Electric TSXPSY5500M is a robust power supply module designed for use within the TSX Micro PLCs series. This module functions within an input voltage range of 200-240 V AC (with limits of 190-264 V) and handles a secondary input of 100-120 V AC (between 85-140 V). It accommodates network frequencies at a nominal frequency of 50/60 Hz and can accept variations within a 47-63 Hz range.

This unit requires an input current of 500 mA at 240 V and 1700 mA at 100 V and can be employed at altitudes of up to 2000 meters above sea level. Humidity tolerance ranges from 10 to 95% during operation and 5 to 95% during storage, ensuring adaptability to various environments. The operating temperature falls within the range of 0 to 60 °C, while it can endure storage temperatures from -25 to 70 °C.

Signaling capabilities are provided via three LEDs: one red LED indicates battery faults, while two green LEDs signal the presence of system voltages, including sensor voltage. The module can manage inrush currents of up to 38 A at both 240 V and 100 V. Total useful secondary power output reaches 50 W, with dedicated outputs of 35 W at 5 V DC for general use and 19 W at 24 V DC for additional components. The module can supply currents of 7 A at 5 V DC and 0.8 A at 24 V DC for both sensor and relay power supplies.

Protection features include an internal time-delayed fuse rated at 4 A and additional safeguards for overloads, overvoltages, and short circuits, ensuring the reliability and safety of connected devices.