Product image is representative; revision or series may vary. Contact us to request a specific version.
The 6SL3210-1KE21-7UB1 inverter drive from Siemens' SINAMICS G120 series accommodates a three-phase AC input. Rated for a line voltage between 380 and 480 volts, this device is adept for a range of industrial applications and requires a line frequency of 47 to 63 Hz.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Siemens |
|---|---|
| Product Line | SINAMICS G120 |
| Part Number | 6SL3210-1KE21-7UB1 |
| UPC | 887621144005 |
| Weight | 2.81 lbs (1.28 kg) |
| Product | Inverter Drive |
| Number of Phases | 3AC |
| Line Voltage | 380 to 480 V |
| Line Frequency | 47 to 63 Hz |
| Rated Current (LO) | 21.50 A |
| Rated Current (HO) | 18.20 A |
| Rated Power (LO) | 7.5 kW |
| Rated Power (HO) | 5.5 kW |
| Max. Output Current | 25 A |
| Pulse Frequency | 4 kHz |
| Power Factor | 0.70 to 0.85 |
| Offset Factor | 0.95 |
| Efficiency | 0.97 |
| Sound Pressure Level | 63 dB |
| Power Loss | 228 W |
The Siemens 6SL3210-1KE21-7UB1 is part of the SINAMICS G120 series of inverter drives. Designed to function in three-phase systems, this model works effectively with a line voltage input ranging from 380 to 480 V. The inverter operates with a line frequency of 47 to 63 Hz, ensuring compatibility across various applications.
It features a rated current of 21.50 Amps under low overload conditions and 18.20 Amps under high overload conditions—capable of offering maximum output currents of 25 A. With rated power reaching 7.5 kW for low overload and 5.5 kW for high overload, it stands out for its performance in demanding operational scenarios.
This inverter drive includes a pulse frequency of 4 kHz and a power factor that varies between 0.70 and 0.85. The offset factor is marked at 0.95, contributing to its overall efficiency rating of 0.97, which reflects its capability in energy management. Additionally, the sound pressure level is measured at 63 dB, providing insight into the operational acoustics of the device. Be aware that the power loss incurred during operation amounts to 228 W, indicating the drive's energy consumption under load conditions.