Free UPS Ground on All Orders!
+1 (919) 205-4392
Siemens SIRIUS 3RV2011-0DA10

Product image is representative; revision or series may vary. Contact us to request a specific version.

3RV2011-0DA10

|

The Siemens 3RV2011-0DA10 circuit breaker is an S00 size device designed to effectively manage and protect electrical circuits. With a rated operating voltage range of 20 to 690V AC, it is adaptable for various applications.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 3RV2011-0DA10

ManufacturerSiemens
Product TypeCircuit Breaker
Product LineSIRIUS
Part Number3RV2011-0DA10
Weight0.63 lbs (0.28 kg)
Circuit Breaker SizeSize S00
Extension Auxiliary SwitchSupported
AC Power Loss in a Hot Operating State5.5 Watts
AC Power Loss In a Per-Pole Hot Operating State1.8 Watts
Insulation Voltage in Pollution Degree 3 Environments690 Volts
Shock Resistance25 g for 11 ms
Rated Surge Voltage Resistance6 kV
Typical Main Contact Mechanical Service Life100,000 Operating Cycles
Typical Auxiliary Contact Mechanical Service Life100,000 Operating Cycles
Typical Electrical Endurance100,000 Operating Cycles
Number of Main Current Circuit Poles3 Poles
Adjustable Current Response Rating for Current-Dependent Overload Release0.22 to 0.23 Amps
Rated Operating Voltage20 to 690V AC

The Siemens 3RV2011-0DA10, classified as a circuit breaker, offers critical overcurrent protection for electrical systems. Being a size S00 unit, it integrates seamlessly into various panels. The device operates within a range of 20 to 690 volts AC, catering to a broad spectrum of industrial needs. It supports an extension auxiliary switch, enhancing its functional capabilities and helps manage circuit conditions.

In hot operating conditions, the total AC power loss is 5.5 watts, while each pole has a power loss of 1.8 watts. Designed for durability, the breaker withstands environmental stresses with a rated insulation voltage suited for pollution degree 3 at 690 volts. It also has exceptional shock resistance rated at 25 g for durations of 11 milliseconds, further ensuring reliable operation in dynamic settings.

The electrical design includes three poles for main current circuits, accommodating heavy loads while the adjustable current response rating for overload release can be set between 0.22 and 0.23 amps. Testing indicates that the typical mechanical life for both the main and auxiliary contacts reaches 100,000 operating cycles, as does the typical electrical endurance, solidifying this circuit breaker's preferred status in reliable electrical protection applications.