Product image is representative; revision or series may vary. Contact us to request a specific version.
The Siemens 6EP3436-8SB00-0AY0 is a three-phase power supply unit within the SITOP series. It is designed to provide reliable DC output voltage at 24 volts, featuring a maximum supply voltage range of 500 volts and a minimum of 400 volts. This unit has a buffering capability of 15 milliseconds, ensuring stable performance during power fluctuations.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Siemens |
|---|---|
| Product Line | SITOP |
| Part Number | 6EP3436-8SB00-0AY0 |
| UPC | 887621882709 |
| Weight | 1.00 lbs (0.45 kg) |
| Product | Power Supply Unit |
| Number of Phases | 3 |
| Minimum Supply Voltage | 400 V |
| Maximum Supply Voltage | 500 V |
| Buffering Time | 15 ms |
| Line Frequency | 50/60 Hz |
| Input Current | 1.2 A |
| Current Limitation | 16 A |
| Output Voltage | 24 V |
| Output Voltage Type | DC |
| Residual Ripple | 100 mV |
| Voltage Peak | 200 mV |
| Display Version | Green LED |
| Response Delay Time | 2.5 s |
| Power Loss | 31 W |
The Siemens part number 6EP3436-8SB00-0AY0 serves as a dependable power supply unit within the SITOP series. This device supports three-phase operation, achieving a voltage range from 400 to 500 volts for its supply. Operating efficiently at a line frequency of either 50 or 60 hertz, it delivers a consistent DC output voltage of 24 volts.
This power supply is built to manage electrical transients effectively, with a buffering time of 15 milliseconds that allows it to maintain output stability during brief interruptions. Its input current is rated at 1.2 amps, ensuring adequate energy flow to the device, while the maximum current limitation is set at 16 amps, safeguarding against overload conditions.
The output characteristics of this unit include a residual ripple voltage of 100 mV, indicating minimal fluctuations in output, and a voltage peak measurement capped at 200 mV. A green LED display enhances visibility, providing status indications to operators. The response delay time is recorded at 2.5 seconds, which denotes the period taken to react to changes in supply conditions. The unit experiences a power loss amounting to 31 watts during operation, reflecting its efficiency in energy management.