Product image is representative; revision or series may vary. Contact us to request a specific version.
The Allen Bradley 1492-SP2C130 is a reliable circuit breaker that falls under the 1492 Wiring System series. It provides a continuous current rating of 13 Amps and operates with a trip curve classified as C Curve, making it suitable for various inductive loads, while allowing maximum voltage ratings of up to 480/277 VAC or 415 VAC based on the standard.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | 1492 Wiring System |
| Part Number | 1492-SP2C130 |
| Weight | 1.81 lbs (0.82 kg) |
| Number of Poles | 2 |
| Continuous Current Rating | 13 Amps |
| Trip Curve | C Curve |
| Maximum Voltage Ratings | 480/277 VAC max. (US), 415 VAC max. (IEC) |
| Supplementary Protector | Yes |
| Magnetic Trip Range | 5 to 10 x the Rated Current for Inductive Loads |
| Switched Neutral Module | Not Included |
| Copper Wire | Required |
| Wire Gauge | #18-8, #6-4 |
The circuit breaker model 1492-SP2C130 from Allen Bradley is engineered to meet diverse electrical protection needs. It is classified under the 1492 Wiring System, featuring a design that accommodates two poles. With a continuous current capacity of 13 Amps, this circuit breaker serves to provide reliable circuit protection in various applications.
The breaker operates under a C Curve trip characteristic, enabling it to handle inrush currents typically encountered with inductive loads. Additionally, it has maximum voltage ratings of 480/277 VAC in US applications and 415 VAC according to IEC standards, ensuring compatibility across various systems. This component also serves as a supplementary protector.
For optimal functionality, the 1492-SP2C130 requires copper connections, with the wire gauge accommodating sizes from #18-8 to #6-4. Note that a switched neutral module is not part of this unit, but its design allows effective protection in conjunction with the appropriate wiring configurations. The magnetic trip range for inductive load protection is set between 5 and 10 times the rated current, making it adaptable to demanding electrical environments.