Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 140G MCB Repair

Allen Bradley 140G MCB Repair

We offer extensive repairs for your 140G MCB. We keep many spare parts in stock so that we can repair your 140G MCB as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 140G MCB and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 140G MCB parts.

Browse 140G MCB Repairs

Browse our catalog of repairable 140G MCB parts to get a quote.

140G-H2H3-D12

This circuit breaker handles currents in the range of 120 A and is rated for insulation up to 1000 V. With a rated impulse withstand voltage of 8 kV, it is designed for various industrial applications

Call

140G-H2H3-D16

This molded case circuit breaker offers electronic LSI protection and supports a current range of 160 A. It features a rated insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. We

Call

140G-H2H4-C25

This device operates within a current capacity range of 25 Amps and has a rated insulation voltage of 1000 V. Additionally, it can withstand impulse voltages up to 8 kV. Weighing 3.53 pounds, it empha

Available

140G-H2H4-C60

Categorized as a four-pole molded case circuit breaker, the 140G-H2H4-C60 is equipped with an electronic LSI protection mechanism. It accommodates a current range of 60 amps and is rated for insulatio

Available

140G-H2H4-D10

This four-pole molded case circuit breaker utilizes electronic LSI protection. It supports a maximum current of 100 A and operates efficiently with a rated insulation voltage of 1000 V. The unit can w

Available

140G-H2H4-D12

Featuring an electronic LSI protection scheme, the 140G-H2H4-D12 operates within a current range of 120 Amps. The insulation voltage rating is 1000 V, and the impulse withstand voltage is rated at 8 k

Available

140G-H2H4-D16

The 140G-H2H4-D16 features four poles and operates within a current range of 160 Amps. With electronic LSI protection, the unit can handle an interrupting capacity of 25 kA. It has a rated insulation

Available

140G-H2I3-C60

This model is crafted for 60 A current range applications. It has a rated insulation voltage of 1000 V and withstands impulse voltages up to 8 kV. A weight of 2.65 lbs makes it suitable for a variety

Call

140G-H2I3-D10

This circuit breaker supports a current range of 100 A and is rated for an insulation voltage of 1000 V. The 140G-H2I3-D10 is capable of withstanding impulse voltages up to 8 kV. This unit weighs 2.65

Call
Showing 301-310 of 1,219 results

About 140G MCB

The Allen-Bradley 140G MCB series is a series of molded case circuit breakers whose usable value can be linked to absolutely all branches of industry, and they can also be implemented in buildings and homes. The 140G circuit breakers are 3-pole or 4-pole protective devices that are available with continuous current ratings between 125 and 3000 Amps. Their maximum operating voltage is 690 Volts AC. For standard electrical installations, customers usually buy circuit breakers with fixed thermal and magnetic protection options, but 140G units are also available with the adjustable thermal/fixed magnetic combination protection feature as well as with the molded case switch (isolator) options. The 140G circuit breaker housing is made of a special plastic that is a good insulator and that is not susceptible to wear and tear due to exposure to high temperatures. The mechanical construction is designed to prevent the jamming of moving parts, thus giving the devices a high level of safety in operation. The lifespan of these molded case circuit breakers is estimated to be over 25,000 mechanical operations.

The Allen-Bradley 140G molded case circuit breakers respond with lightning speed to the appearance of short-circuits, and the force separating the contacts inside of these units is proportional to the current flowing through them, so the speed of contact separation increases with the increase of the short-circuit current to which the device needs to respond. Internal options that can be factory installed on the 140G series circuit breakers are shunt trip, undervoltage release, alarm contacts, and auxiliary contacts. All the products from this series can be reverse-fed, which simplifies the installations in some applications. Allen-Bradley has certified that the 140G series circuit breakers with all their accessories meet the CE, UL, CSA, IEC, and the CCC standards.