Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 140G MCB Repair

Allen Bradley 140G MCB Repair

We offer extensive repairs for your 140G MCB. We keep many spare parts in stock so that we can repair your 140G MCB as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 140G MCB and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 140G MCB parts.

Browse 140G MCB Repairs

Browse our catalog of repairable 140G MCB parts to get a quote.

140G-I2C4-D16

This molded case circuit breaker features a four-pole design and utilizes fixed thermal and fixed magnetic protection types. It supports a thermal trip setting of 160 A and handles magnetic trips up t

Call

140G-I2C4-D17

This circuit breaker features four poles and operates within a current range of 170 A, providing fixed thermal and magnetic protection. It interrupts fault currents up to 25 kA and meets insulation vo

Call

140G-I2C4-D20

With four poles, this circuit breaker operates within a current range of 200 Amps. It includes fixed thermal and magnetic trip mechanisms for robust protection. Rated for 800 volts of insulation and 8

Call

140G-I2C4-D22

This circuit breaker features a four-pole configuration and includes both fixed thermal and magnetic protection types. It is rated for insulation voltage up to 800 volts and can withstand impulse volt

Call

140G-I3C3-C60

This molded case circuit breaker is designed within an I frame, providing a versatile 225 amp rating. It features a maximum interrupting capacity of 35 kA. The 140G-I3C3-C60 also has a current range o

Call

140G-I3C3-C63

This circuit breaker features an I frame and utilizes fixed thermal and fixed magnetic protection types. It operates within a current range of 63 A, with a thermal trip threshold of 63 A and a magneti

Call

140G-I3C3-C70

This circuit breaker operates at a maximum rated insulation voltage of 800 volts with a thermal trip setting of 70 A and a magnetic trip setting reaching 700 A. The frame type is classified as Frame I

Call

140G-I3C3-C80

This circuit breaker features a frame size I and an interrupting rating of 35 kA. It supports a fixed thermal trip setting at 80 A, while the magnetic trip can handle up to 800 A. Its insulation volta

Call

140G-I3C3-C90

This circuit breaker employs fixed thermal and fixed magnetic protection mechanisms. It has a thermal trip set at 90 A and magnetic trip set at 900 A. This model is rated for insulation up to 800 volt

Call

140G-I3C3-D10

This circuit breaker is equipped with fixed thermal and magnetic protection types, and it can manage a current range of 100 A. It is rated for an insulation voltage of 800 V and withstands impulse vol

In Stock Ships Today
Showing 541-550 of 1,219 results

About 140G MCB

The Allen-Bradley 140G MCB series is a series of molded case circuit breakers whose usable value can be linked to absolutely all branches of industry, and they can also be implemented in buildings and homes. The 140G circuit breakers are 3-pole or 4-pole protective devices that are available with continuous current ratings between 125 and 3000 Amps. Their maximum operating voltage is 690 Volts AC. For standard electrical installations, customers usually buy circuit breakers with fixed thermal and magnetic protection options, but 140G units are also available with the adjustable thermal/fixed magnetic combination protection feature as well as with the molded case switch (isolator) options. The 140G circuit breaker housing is made of a special plastic that is a good insulator and that is not susceptible to wear and tear due to exposure to high temperatures. The mechanical construction is designed to prevent the jamming of moving parts, thus giving the devices a high level of safety in operation. The lifespan of these molded case circuit breakers is estimated to be over 25,000 mechanical operations.

The Allen-Bradley 140G molded case circuit breakers respond with lightning speed to the appearance of short-circuits, and the force separating the contacts inside of these units is proportional to the current flowing through them, so the speed of contact separation increases with the increase of the short-circuit current to which the device needs to respond. Internal options that can be factory installed on the 140G series circuit breakers are shunt trip, undervoltage release, alarm contacts, and auxiliary contacts. All the products from this series can be reverse-fed, which simplifies the installations in some applications. Allen-Bradley has certified that the 140G series circuit breakers with all their accessories meet the CE, UL, CSA, IEC, and the CCC standards.