Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 140G MCB Repair

Allen Bradley 140G MCB Repair

We offer extensive repairs for your 140G MCB. We keep many spare parts in stock so that we can repair your 140G MCB as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 140G MCB and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 140G MCB parts.

Browse 140G MCB Repairs

Browse our catalog of repairable 140G MCB parts to get a quote.

140G-J0C4-C40

This circuit breaker features four poles and offers effective electrical protection utilizing both fixed thermal and magnetic trip mechanisms. With a current range of 40 amperes, it is compatible with

Call

140G-J0C4-C50

This four-pole circuit breaker operates within a current range of 50 amps and incorporates fixed thermal and magnetic protection mechanisms. It supports a rated insulation voltage of 1000 volts and wi

Call

140G-J0C4-C60

This model is equipped with 4 poles and is capable of interrupting currents at a staggering 100 kA level. Designed for a current range of 60 A, it provides reliable protection against faults. The rate

Call

140G-J0C4-C63

This model is equipped with four poles and provides fixed thermal and magnetic protection mechanisms. The device operates effectively within a current range of 63 A and is rated for insulation voltage

Call

140G-J0C4-C70

This device utilizes a four-pole configuration and features fixed thermal and magnetic protection mechanisms. It supports a current range of 70 Amps and is rated for insulation at 1000 Volts. The impu

Call

140G-J0F3-C80

With a frame size designated as J, this circuit breaker operates within an adjustable current range of 80 Amps. It supports a rated insulation voltage of 1000 volts and can endure impulse withstand vo

Call

140G-J0F3-C90

This molded case circuit breaker operates within a current range of 90 A, featuring a rated insulation voltage capacity of 1000 volts. It is designed to withstand impulse voltages up to 8 kV. The unit

Call

140G-J0F3-D10

This model operates within a current range of 100 A and includes adjustable thermal and magnetic protection. Designed to withstand insulation voltage ratings of 1000 V and impulse withstand voltages u

Call

140G-J0F3-D11

This circuit breaker operates effectively within a current range of 110 A. It offers adjustable thermal and magnetic protection types, with a rated insulation voltage of 1000 V. The impulse withstand

Call
Showing 591-600 of 1,219 results

About 140G MCB

The Allen-Bradley 140G MCB series is a series of molded case circuit breakers whose usable value can be linked to absolutely all branches of industry, and they can also be implemented in buildings and homes. The 140G circuit breakers are 3-pole or 4-pole protective devices that are available with continuous current ratings between 125 and 3000 Amps. Their maximum operating voltage is 690 Volts AC. For standard electrical installations, customers usually buy circuit breakers with fixed thermal and magnetic protection options, but 140G units are also available with the adjustable thermal/fixed magnetic combination protection feature as well as with the molded case switch (isolator) options. The 140G circuit breaker housing is made of a special plastic that is a good insulator and that is not susceptible to wear and tear due to exposure to high temperatures. The mechanical construction is designed to prevent the jamming of moving parts, thus giving the devices a high level of safety in operation. The lifespan of these molded case circuit breakers is estimated to be over 25,000 mechanical operations.

The Allen-Bradley 140G molded case circuit breakers respond with lightning speed to the appearance of short-circuits, and the force separating the contacts inside of these units is proportional to the current flowing through them, so the speed of contact separation increases with the increase of the short-circuit current to which the device needs to respond. Internal options that can be factory installed on the 140G series circuit breakers are shunt trip, undervoltage release, alarm contacts, and auxiliary contacts. All the products from this series can be reverse-fed, which simplifies the installations in some applications. Allen-Bradley has certified that the 140G series circuit breakers with all their accessories meet the CE, UL, CSA, IEC, and the CCC standards.