We offer extensive repairs for your 140G MCB. We keep many spare parts in stock so that we can repair your 140G MCB as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 140G MCB and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 140G MCB parts.

Browse 140G MCB Repairs

Browse our catalog of repairable 140G MCB parts to get a quote.

140G-JTI3-D10

The 140G-JTI3-D10 design includes a robust electronic LSIG protection feature. It operates with a rated current of 100 Amps while maintaining an electrical life rating of 120 operations per hour. This

Call

140G-JTI3-D15

The 140G-JTI3-D15 belongs to the J frame product line and has a rated current of 150 Amps. This circuit breaker is rated for an insulation voltage of 1000 volts and can withstand an impulse voltage of

Call

140G-JTI3-D25

This J-frame breaker offers an interrupting rating supported by its trip unit, ensuring effective operation in various electrical environments. It is rated for insulation voltages of up to 1000 volts

Call

140G-JTI4-C40

The 140G-JTI4-C40 breaker model has four poles and supports a rated current of 40 A. It has an insulation voltage rating of 1000V and is designed to handle impulse withstand voltages up to 8 kV. The d

Call

140G-JTI4-C60

This molded case circuit breaker operates with four poles and supports a rated current of 60 amps. It is configured for a rated insulation voltage of 1000 volts and withstands impulse voltages of up t

Call

140G-JTI4-D10

This breaker operates with a maximum current capacity of 250 Amps and incorporates a trip unit for effective fault interruption. It supports an insulation voltage rating of 1000 volts and can withstan

Call

140G-JTI4-D15

With a 4-pole configuration, this breaker model offers advanced overload protection through its trip unit. It operates efficiently at a rated insulation voltage of 1000 volts and withstands impulse vo

Call

140G-JTI4-D25

This circuit breaker is structured with a J frame and contains four poles. It operates with a current rating of 250 Amps. It is rated for up to 100V of insulation voltage, and it can also endure impul

Call

140G-K-EA1R1A

This accessory features two poles and includes one alarm contact with an additional auxiliary contact for enhanced functionality. It is compatible with frame sizes K and M, and supports inside right c

In Stock Ships Today

140G-K-FCS06

This molded case circuit breaker has a K frame size and is equipped with a stainless steel flange handle for durability. It operates effectively within a temperature range from 0°C to 40°C and can be

Call
Showing 941-950 of 1,219 results

About 140G MCB

The Allen-Bradley 140G MCB series is a series of molded case circuit breakers whose usable value can be linked to absolutely all branches of industry, and they can also be implemented in buildings and homes. The 140G circuit breakers are 3-pole or 4-pole protective devices that are available with continuous current ratings between 125 and 3000 Amps. Their maximum operating voltage is 690 Volts AC. For standard electrical installations, customers usually buy circuit breakers with fixed thermal and magnetic protection options, but 140G units are also available with the adjustable thermal/fixed magnetic combination protection feature as well as with the molded case switch (isolator) options. The 140G circuit breaker housing is made of a special plastic that is a good insulator and that is not susceptible to wear and tear due to exposure to high temperatures. The mechanical construction is designed to prevent the jamming of moving parts, thus giving the devices a high level of safety in operation. The lifespan of these molded case circuit breakers is estimated to be over 25,000 mechanical operations.

The Allen-Bradley 140G molded case circuit breakers respond with lightning speed to the appearance of short-circuits, and the force separating the contacts inside of these units is proportional to the current flowing through them, so the speed of contact separation increases with the increase of the short-circuit current to which the device needs to respond. Internal options that can be factory installed on the 140G series circuit breakers are shunt trip, undervoltage release, alarm contacts, and auxiliary contacts. All the products from this series can be reverse-fed, which simplifies the installations in some applications. Allen-Bradley has certified that the 140G series circuit breakers with all their accessories meet the CE, UL, CSA, IEC, and the CCC standards.