Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley Panelview Plus 1500 Repair

Allen Bradley Panelview Plus 1500 Repair

We offer extensive repairs for your PV Plus 1500. We keep many spare parts in stock so that we can repair your PV Plus 1500 as efficiently and effectively as possible. Our standard repair lead time is 3-5 days. However, we can often repair your unit much faster if necessary. We can repair most issues with your PV Plus 1500 and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your Panelview Plus 1500 parts.

Browse Panelview Plus 1500 Repairs

Browse our catalog of repairable Panelview Plus 1500 parts to get a quote.

2711P-B15C4A7

This HMI terminal allows for input via a keypad comprising 40 keys, identified as F1-F20 and K1-K20. For processing capabilities, it contains a processor module with 256 MB of CE logic. Its memory con

In Stock Ships Today

2711P-B15C4A7X

This operator terminal supports both keypad and touchscreen interfaces, making it adaptable for different user preferences. It operates within a temperature range of 0 to 55 °C and is mounted in panel

In Stock Ships Today

2711P-B15C4B1

This unit comes equipped with a 15-inch color TFT display, boasting a resolution of 1024 x 768 pixels. Communication capabilities include Ethernet with speeds of 10/100 Mbps, along with RS-232 and USB

In Stock Ships Today

2711P-B15C4B1X

This terminal operates with an input power supply from 100 to 240 VAC or 18 to 32 VDC and has RAM and flash memory capacities of 64 MB. It functions effectively within an operating temperature range o

In Stock Ships Today

2711P-B15C4B2

This operator interface features a vibrant color active-matrix TFT display with a 1024 × 768 pixel resolution. It includes 40 programmable function keys and utilizes both a resistive analog touchscree

In Stock Ships Today

2711P-B15C4B2X

This device operates within an input voltage range of 100–240 VAC or 18–32 VDC. It features a storage temperature tolerance from -25 to 85 °C and is designed to work efficiently within a relative humi

In Stock Ships Today

2711P-B15C4D1

This interface terminal features a 15-inch color TFT LCD display with a resolution of 1024 × 768. It provides 64 MB of logic module memory, ensuring smooth operation with an 18-bit color depth. It sup

In Stock Ships Today

2711P-B15C4D1X

This operator interface terminal operates with a 15-inch display, offering a clear resolution of 1024 x 768. It supports both keypad and touchscreen inputs for enhanced usability. The enclosure rating

In Stock Ships Today

2711P-B15C4D2

This terminal operates within a temperature range of 0 to 55 °C and can withstand non-operating conditions between -20 and 70 °C. It can handle vibrations up to 2 G and shocks of 15 G when in operatio

In Stock Ships Today

2711P-B15C4D2X

The 2711P-B15C4D2X is designed as an operator interface with a 15-inch color display. It supports a screen resolution of 1024 x 768 pixels. The unit incorporates a keypad for user input and features b

In Stock Ships Today
Showing 31-40 of 207 results

About Panelview Plus 1500

Manufactured by Allen-Bradley, the PV Plus 1500 terminal series is a PanelView series of human-machine interface terminals.  The 15-inch display terminals come with the keypad and touchscreen input options. The PV Plus 1500 terminals support graphic color-display modules, and they come with analog-resistive touchscreens when they have a touchscreen. These units feature the EtherNet and Serial communication ports, with modular communication interfaces for ensuring an easy add-on capability. The Allen-Bradley PV Plus 1500 terminals coms with the memory expansion modules for providing a user field upgrade of up to 256 MB of RAM and they also support the 512 MB compact flash memory. The PV Plus 1500 terminals support CompactFlash card slots that support the Type 1 CompactFlash cards.

The PV Plus 1500 terminals use USB ports to provide support for external devices that include a keyboard, a mouse, or a printer. The PV Plus 1500 terminals come with similar panel cutouts to the ones that the PanelView Standard terminals and the PanelView enhanced terminals have. The PV Plus 1500 terminals use the network interface that can be attached to the base-configured units of the terminals. This increases the communication capabilities of the terminals with the DH+ or the DH-485 networks and the ControlNet networks. The communication modules can be installed easily on the top of the logic modules or at the back of the terminals. The PV Plus 1500 PanelView terminal series provides application flexibility and the terminals come with up to 3 available power options. The supported power options include AC power, unisolated DC power, and isolated DC power. The PV 1500 series terminals provide an integral antiglare overlay with all displays built to support common features for ensuring easy device integration.

We can repair your Panelview Plus 1500 with the following error codes:

Error 1 Ram Test- Ram Test Failure

Error 3a Stuck Touch -Touchscreen Failure

Error 23 Download Task/INternal CF

Error 24 CRC check- Checksum Test Failed

Error 30 Watchdog Test- Watchdog Test Faild to Pass

Error 31 Stuck Key- A function key has faild or is stuck

Error 31.5 Touchscreen Failure

Error 32  Battery Test, Battery has failed or is Dead

Error 33.5 NVRAM Access- Nonvolatile memory has failed

Error 40 EXE Check- System Failure/Corrupt

And many more Errors