Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
Designed within the Series G Circuit Breakers line, this unit includes a T186 trip type for precise fault detection. This breaker showcases impressive interrupt ratings, with 85 KAIC at 240 VAC, 35 KAIC at 480 VAC, and 22 KAIC at 600Y/347 VAC. Its frequency operation ranges from 50 to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and incorporates fixed thermal and fixed magnetic trip characteristics to ensure reliable protection. It has an interrupt rating of 65 kAIC at 240 V and 35 kAIC at 480 V, making it suitable for handling significant fault conditions. The KD3150 operates with
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker operates at a voltage of 600 VAC and is configured with three poles. The PDG23F0060TFFJ includes both long-time and instantaneous trip functions, making it versatile for various applications. With a significant interrupt rating of 25 kAIC at 480 VAC, it ensures safe operation in
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory, suitable for Frame J-K size applications, includes a magnetic trip range of 45 to 150 A. It operates at an AIC rating of 65 kA at 480V and supports a feed-thru connection type. Designed for an environment with humidity levels up to 80% (non-condensing), it is installed at an altitude
Eaton Cutler-Hammer / PLCs / Power Defense
Designed for use with PD2 breaker frames, this enclosure is constructed from metal. It supports humidity levels up to 80% and can be installed at altitudes up to 1000 meters above sea level. The operating temperature range is between 0°C and 40°C.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a mechanical operating mechanism, this auxiliary switch can be mounted on either the left or right pole configuration. It utilizes a terminal block connection style and provides auxiliary contacts configured as 2A/2B. This product is UL-approved and designed for field mounting to facilitat
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This MCCB accessory consists of three poles and operates efficiently within a magnetic trip range of 750 to 2500 A. It is UL Listed, ensuring compliance with safety standards. The device is specifically intended for motor protection, and it connects via lugs while being mounted on panels.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features one pole and uses a G frame design, suitable for various applications. It has a thermal magnetic protection mechanism and offers long-time and instantaneous trip functions. Its interrupting capacity at 277 VAC is rated at 14 KAIC, ensuring reliable performance for overc
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory is utilized in three-pole configurations and is compatible with molded case circuit breakers. It ensures reliable functioning within an operating temperature range of 0°C to 40°C. For storage, temperatures should also be maintained between 0°C and 40°C to preserve integrity.
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker operates at a voltage of 120/240 Volts AC and has an interrupt rating of 42 kA at 240 Volts AC. It's suitable for connecting wire sizes from 4 AWG to 2/0 AWG. The device is equipped with a thermal magnetic trip unit and utilizes a handle actuator to manage operations effectively