1289 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a compact F frame design, this device includes two poles and is rated for an impressive 150 Amps. It accommodates a frequency range between 50 Hz and 60 Hz. The circuit breaker is equipped with high interrupting capabilities, rated at 100 KAIC for 240 VAC and 65 KAIC for 480 VAC, ensuring
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip type and is constructed with a Frame G size. Designed with two poles, it is compatible with a frequency range of 50 to 60 Hz. The interrupting capacity is rated at 65 KAIC for 240 VAC and 14 KAIC for 480Y/277 VAC, providing reliable protection against electr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed with a K frame, the KDB3350 is specified for a frequency range from 50 Hz to 60 Hz. It features line and load terminals made from aluminum. The trip type is designated as T186 and it has an interrupting capacity of 65 KAIC at 240 VAC and 35 KAIC at 480 VAC.
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker features two poles and is designed for single-phase systems. It utilizes a common trip type with thermal magnetic protection. The BRH290 can handle interruptions up to 22 KAIC, ensuring reliable operation under fault conditions. It includes long-time and instantaneous trip funct
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for single-pole applications, this field-mounted undervoltage release operates efficiently within a frequency range of 50 to 60 Hz. The connection type is pigtail lead, and the unit is certified by UL, which is indicative of its adherence to established safety standards.
Eaton Cutler-Hammer / PLCs / Power Defense
This molded case circuit breaker, part of the Power Defense series, features a thermal magnetic trip unit. It includes three poles and a feed-thru connection type, making it versatile for various configurations. The interrupt rating of 25 kiloamperes at 480 volts AC ensures robust protection during
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This two-pole circuit breaker utilizes a T186 trip type and offers a frame classified as F. It supports frequency ranges from 50 Hz to 60 Hz. For fault protection, the FDB2025 has an interrupt rating of 14 kAIC at 480 V and 18 kAIC at 240 V.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip type, combining fixed thermal and magnetic functions. It is configured with three poles and facilitates a line and load terminal arrangement, using aluminum for terminal construction. The J frame design supports frequency ratings from 50 Hz to 60 Hz, and it
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features a thermal magnetic mechanism with a fixed trip unit. It consists of three poles, allowing for effective branch circuit protection in 3-phase systems. The line-side is terminated using a busbar, while lugs are used for load-side connections. Compliance with UL, CSA, and
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features three poles and incorporates both thermal and magnetic trip functions. It is compliant with UL and CSA standards and has an interrupt rating of 25 kAIC at 240 VAC and 18 kAIC at 480 VAC. The unit has a fixed trip mechanism and utilizes a bolt-on connection type.