197 results
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker operates effectively with an interrupt rating of 25 kAIC at 240 Vac and 18 kAIC at 480 Vac. It incorporates thermal elements for overload protection and features a trip type designated as T186. The device is UL Listed and CSA Certified, assuring compliance with safety standards.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker is engineered with 3 poles and offers substantial interrupting capacities: 125 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. Its trip unit employs solid-state technology with LSI functions (long-time, short-time, instantaneous) and can be fully adjusted with a rat
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This model features a trip type T186 and operates within a frequency range of 50 to 60 Hz. The EGH3050FFB is configured for three-phase power systems and supports a bolt-on connection type. Its interrupt ratings are substantial, reaching 35 KAIC at 600Y/347 VAC, 100 KAIC at 240 VAC, and 65 KAIC at 4
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features three poles and utilizes a trip mechanism that includes fixed thermal and fixed magnetic options. It is designed to handle various voltage levels, exhibiting interrupting capacities of 85 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 22 kAIC at 600Y/347 VAC.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features a three-pole configuration and is designed for panel mounting. The EGB3060FFB has an interrupt rating of 25 kA at 240 volts and 18 kA at 480 volts. It has a current capacity of 60 amps with bolt-on connections for both line and load sides.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker offers robust protection with an interrupt rating of 85 KAIC at 240 VAC and 35 KAIC at 480 VAC, alongside a 22 KAIC rating for 600Y/347 VAC applications. It operates effectively between 50 Hz and 60 Hz, and features a bolt-on terminal type for secure connectivity.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
Engineered with three poles, the NGC308033EC has an interrupting capacity of 100 kA at 480 VAC and 200 kA at 240 VAC. It operates efficiently within a frequency range of 50 to 60 Hz, making it suitable for various industrial environments.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker operates across three poles and includes both fixed thermal and fixed magnetic trip types. It provides an interrupting capacity of 85 kAIC at 240 VAC and 35 kAIC at 480 VAC, with a rating of 22 kAIC for 600Y/347V AC. The device functions within an operational frequency range fro
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This product features three poles and utilizes fixed thermal and magnetic trip units. It is capable of handling an impressive interrupt rating of 35 kAIC at 600Y/347 VAC, making it suitable for demanding applications. The breaker operates at frequencies of 50 to 60 Hz and is compatible with both the
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features three poles in its EG frame design, optimal for industrial usage. It has a frequency rating of 50/60 Hz and deploys trip technology with both fixed thermal and fixed magnetic options. The interrupt ratings are considerable at 200 kAIC for 240 Vac, 100 kAIC for 480 Vac,