Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This two-pole circuit breaker utilizes a G frame design and includes connections via lugs on the load side and screw terminals on the line side. Its interrupt ratings are 14 kA at 480 Volts AC and 65 kA at 240 Volts AC, and it features a thermal magnetic trip unit for both long-time and instantaneou
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with three poles, the FD3080 features a T186 trip type and is suitable for a frequency range of 50 to 60 Hz. Its interrupt ratings are notable: 35 KAIC at 480 V and 65 KAIC at 240 V, ensuring significant protection against fault conditions. This circuit breaker utilizes load side terminal c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This GHB circuit breaker operates efficiently with a voltage rating of 480Y/277 volts AC and 125/250 volts DC. It is rated for 50/60 hertz operation and delivers an interrupt rating of 14 kAIC at 480Y/277 V AC and 65 kAIC at 240 V AC. It accommodates wire sizes from AWG #10 to 1/0 for both copper an
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The MT3700T trip unit is characterized by its three-pole configuration, providing robust protection for compatible MDL, HMDL, and HMDLDC breaker frames. This unit employs thermal magnetic technology, with fixed and non-adjustable trip adjustments ensuring reliability. Its installation is accomplishe
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model fits in the Series C Circuit Breakers and has a frame type designated as F. It supports voltages up to 600 VAC and 250 VDC while providing significant interrupt ratings. The breaker can interrupt 18 kA at 240 VAC and maintains a consistent performance with 14 kA at both 480 VAC and 600 VA
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker accessory features three poles and is designed with a J-K frame type. Its AIC rating is rated at 65 KA at 480 V, ensuring significant fault current handling capability. The humidity tolerance is set at 80% for both operating and storage conditions, making it versatile for variou
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a 2-pole design and supports a frequency range from 50 Hz to 60 Hz. It operates effectively at a rated current of 100 A with an interrupt rating of 42 KAIC at 240 VAC. The breaker is constructed for load side terminals, making it suitable for various installation types.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory is utilized in three-pole configurations and is compatible with molded case circuit breakers. It ensures reliable functioning within an operating temperature range of 0°C to 40°C. For storage, temperatures should also be maintained between 0°C and 40°C to preserve integrity.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The MT3350T is specially designed for three-pole applications and fits within frame sizes J–K. It functions efficiently at operating frequencies up to 60 Hz, with a minimum rating of 50 Hz. The trip unit is rated for maximum operating conditions of 40°C and can withstand humidity levels of 85% witho
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has a rated current of 35 A and features a thermal-magnetic trip unit with fixed thermal and fixed magnetic settings. It utilizes load-side lugs for connections and employs a bolt-on mounting method. The EHD3035 provides a 14 kAIC interrupting capacity at 480 Vac and an 18 kAIC