Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker includes three poles and employs a bolt-on mounting type for secure installation. Powered by a Digitrip 310 RMS electronic LSI trip unit, it supports long-time, short-time, and instantaneous trip functions for versatile protection. Its interrupting capacity is rated at 65 kAIC f
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features electronic and adjustable trip types, ensuring optimal protection against both overloads and short circuits. The A6LES600T1 meets UL and CSA standards, affirming its reliability in various applications. Additionally, it is designed for simple plug-in installation and uses an int
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Occupying a K-frame size, the KDC3400 integrates a three-pole configuration designed for use in various electrical systems. The circuit breaker is rated for 50/60 Hz operation and can handle DC voltage up to 250 V. It has interrupting capacity ratings of 200 kAIC at 240 Vac and 100 kAIC at 480 Vac.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a three-pole configuration for 3-phase installations. It delivers an interrupting capacity of 22 kAIC at 480 VAC and 65 kAIC at 240 VAC, ensuring reliable fault interruption. The trip mechanism employs both fixed thermal and fixed magnetic types, with a long-time and in
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed with two poles and a rated trip current of 80 A. It features a thermal magnetic trip unit for effective protection. The interrupt ratings are 18 kA at 240 volts AC and 14 kA at 240 volts DC. It includes lugs for load-side connections and utilizes a busbar for the lin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features one pole and operates on a single-phase basis. The frame designation is G Frame, and it employs fixed thermal and fixed magnetic trip units. An interrupt rating of 14 kAIC at 277 VAC enhances its ability to protect the circuit under fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features a thermal magnetic trip type and is designed with three poles, which accommodates three-phase systems. With an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, it provides substantial protection against short-circuit conditions. The F frame construction ensures
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This electronic molded case circuit breaker is designed with a solid-state trip unit and features a three-pole configuration. It is rated for 160 Amps with an AC voltage capability of up to 600 V and a DC rating of 250 V. The interruption capacity is noteworthy at 65 kAIC for 240V AC and 35 kAIC for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release device is designed for internal mounting on the left pole. It utilizes pigtail leads for connections and can function within a temperature range from -20 °C to +60 °C. For storage, it can withstand temperatures as low as -30 °C and as high as 70 °C.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and delivers reliable operation across multiple frequency settings ranging from 50 Hz to 60 Hz. Designed with fixed thermal and magnetic trip types, it incorporates long-time and instantaneous trip functions. The device also showcases high interrupting capacit