Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Engineered as a part of Eaton’s Series C circuit breakers, this unit possesses a frame type classified as F. Its interrupt rating at 240 volts is rated at 42 kAIC. Designed to operate efficiently between frequencies of 50 to 60 Hz, this breaker supports load-side connections.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Operating under IEC standards, the EHD1050 breaker includes a thermal magnetic trip type with both long-time and instantaneous functions. Its AIC ratings are 14 kA at 480 volts AC and 18 kA at 240 volts AC. The breaker is mounted in an F frame and uses feed-thru lugs for connections. It complies wit
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This K Frame breaker features a thermal magnetic trip type for reliable operation. With an interrupting capacity of 100 kAIC at 240 VAC and 10 kAIC at 250 VDC, this device ensures adequate protection for critical circuits. It functions effectively within a frequency range of 50 Hz to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and delivers reliable operation across multiple frequency settings ranging from 50 Hz to 60 Hz. Designed with fixed thermal and magnetic trip types, it incorporates long-time and instantaneous trip functions. The device also showcases high interrupting capacit
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The FD2050 is configured as a two-pole circuit breaker designed to handle AC voltages of 600 VAC. It has impressive interrupting capacities of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. Integral trip types include fixed thermal with instantaneous long-time (LI) responsiveness, which enhances its rel
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit employs fixed thermal and fixed magnetic settings. With its three-pole configuration, the FDC3175 offers significant interrupting capabilities, rated at 200 kAIC for 240 VAC, 100 kAIC for 480 VAC, and 25 kAIC for 600 VAC. It includes load side lugs for easy terminal connections.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector is equipped with a magnetic-only trip mechanism, providing reliable primary protection. The unit offers an adjustable trip setting range between 500 and 1500 A, facilitating integration into various systems. It accommodates motor full-load amps from 38 to 84.5 A and ensu
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker offers a maximum AC voltage rating of 600 VAC and a DC rating of 250 VDC, making it suitable for a variety of applications. The device has three poles and features a fixed thermal and magnetic trip unit, providing long-time and instantaneous trip functions. Interrupting ratings
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With three poles, the KCDPKB circuit breaker is compatible with JB, KB, and HKB frames. It functions within temperatures from 0 to 40 degrees Celsius. Additionally, it can be stored and utilized in humid environments with levels up to 80% (non-condensing) and is rated for installations at altitudes
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a dual-pole configuration in an F-frame type. The device utilizes a thermal magnetic trip mechanism for dependable protection. It has busbar terminations on the line side and lugs for connection on the load side, facilitating panel mounting and compliance with UL standa