Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With three poles, the KCDPKB circuit breaker is compatible with JB, KB, and HKB frames. It functions within temperatures from 0 to 40 degrees Celsius. Additionally, it can be stored and utilized in humid environments with levels up to 80% (non-condensing) and is rated for installations at altitudes
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model is compatible with J-K frame sizes and operates at AC voltages ranging from 110 to 240 V and at 110 to 125 V DC. The unit features pigtail leads for connection and can be mounted on either the left or right. It is rated to function under operating temperatures between 0°C and 40°C and sup
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and operates on a three-phase system. It utilizes thermal-magnetic trip technology for protection against overloads. The interrupting capacity is rated at 200 kAIC for 240 VAC and at 100 kAIC for 480Y/277 VAC, providing robust performance in fault conditions
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Configured with two poles, the GHB2045 features a thermal magnetic trip unit for reliable long-time and instantaneous protection. It accommodates a remarkable interrupting capacity of 65 kA at 240 Volts AC and 14 kA at higher voltage levels. The unit is designed for bolt-on connections and includes
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is part of the Series C lineup and operates within a frequency spectrum of 50 to 60 Hertz. It has a thermal magnetic trip type classified as T186 and utilizes load side terminals for connectivity. The interruption capacity is rated at 14 kAIC for 240 V and 18 kAIC for 480 V, ens
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed to accommodate three poles, this mounting kit functions efficiently within an operating frequency range of 50 to 60 Hz. It has a maximum anticipated operating temperature of 40°C and is constructed from durable copper connectors and mounting brackets. Additionally, the kit is rated for a hi
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker, with two poles, is engineered for flexibility, allowing operation within a frequency range of 50 to 60 Hz. It uses a T186 trip mechanism for dependable circuit protection. The frame type is designated as F, and it features load-side terminals. It has an interrupt rating of 100
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a maximum voltage capacity of 600 VAC, this circuit breaker utilizes a fixed instantaneous trip adjustment. It boasts an interrupting capacity of 35 kAIC at 480 VAC and operates efficiently at 50/60 Hz. The construction features a bolt-on mounting style, and the typical electrical endurance all
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and employs a T186 trip type. It has an interrupt rating of 22 kAIC at 240 VAC, which is crucial for protecting circuits from excess current. The breaker is designed for use in 3-phase systems and maintains operational efficiency in humidity levels up to 80%
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The A1L2RPK is tailored for JD Frame types and allows for right-hand mounting. It supports an amperage range of 0.25, 0.5, and 6 A and features a contact configuration of 1MK and 1BK. This alarm switch can function effectively in environments with an operating and storage humidity level of up to 80%