714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and utilizes fixed thermal and magnetic trip options. It has a frame size classified as F and a weight of 4.5 lbs. The interrupting capacity is rated at 18 kAIC for 240 VAC and 14 kAIC for 480 VAC, ensuring safe operation under fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features an F frame design and utilizes a thermal-magnetic trip mechanism for effective overload protection. It has an interrupting capacity of 65 kAIC at 240 VAC, ensuring safe operation under fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates on a 1-phase system and includes two poles for effective protection. Capable of handling temperatures up to 40 degrees Celsius, the FDB2080 is equipped with load-side terminals and adheres to T186 trip standards. The interrupt ratings are significant at 14 kAIC for 480
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit is rated for two poles and operates efficiently within a frequency range of 50 to 60 Hz. Its insulation voltage is rated at 600 VAC with a withstand voltage of 8 kV. It is built to perform in environments with up to 95% humidity and is suited for altitudes of up to 2000 meters.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with fixed thermal and magnetic trip types, this breaker has an interrupting capacity of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. The load side features standard lug terminals for easy connections, and it is lightweight at just 3 lbs.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features two poles for effective circuit management. It is rated for 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, providing robust performance under fault conditions. The EHD2080L is built with fixed thermal and fixed magnetic trip types for reliable operations and is suitable for 50 to 60 H
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and operates within the 50 to 60 Hz frequency range. Its fixed thermal and fixed magnetic trip mechanisms offer dependable protection. The FDB3100L has an interrupting capacity of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, ensuring safety during overload con
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole breaker is housed within a Frame G and features a trip type of T186. It can handle frequency ratings of both 50 and 60 Hz, and offers impressive interrupt ratings of 65 kAIC at 240 Vac and 14 kAIC at 480Y/277 Vac. The unit is bolt-mounted and accommodates wire sizes ranging from 14 A
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles and features an electronic LSG trip type for enhanced safety. It is rated for frequencies between 50 Hz and 60 Hz. This device functions correctly in environments with humidity levels of up to 80% without condensation. The frame type is classified as F.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker features an AC voltage rating of 600 VAC and a DC rating of 250 VDC. It includes thermal-magnetic trip units with long-time and instantaneous functions. The device is rated to interrupt currents up to 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC at 600 VAC, e