89 results
Eaton Cutler-Hammer / PLCs / QuickLag
This model employs a thermal magnetic trip mechanism and has no interchangeable trip options. With an interrupting rating of 10 kAIC, it is HACR rated and complies with UL and CSA certifications, ensuring reliability in demanding environments.
Eaton Cutler-Hammer / PLCs / QuickLag
This two-pole GFCI features a thermal-magnetic trip characteristic for reliable performance. It is designed specifically for use with QO Series enclosures and has a load wire size compatibility ranging from #14 to #8 AWG for copper conductors. The interrupt rating of this breaker stands at 10 kAIC,
Eaton Cutler-Hammer / PLCs / QuickLag
This circuit breaker has a non-interchangeable trip type and an interrupt rating of 10 KAIC. It is designed to protect against ground faults with a trip sensitivity of 30 mA. The device utilizes thermal magnetic protection and offers long time and instantaneous trip functions. It features cable-in/c
Eaton Cutler-Hammer / PLCs / QuickLag
The BAB2020S is tailored with two poles and is equipped with a non-interchangeable trip type. This circuit breaker includes shunt trip functionality and mounts using a bolt-on method. It offers an interrupting capacity of 10 kAIC and is HACR-rated, ensuring compatibility with heating, air conditioni
Eaton Cutler-Hammer / PLCs / QuickLag
This two-pole circuit breaker utilizes a thermal-magnetic protection mechanism and is intended for use in single-phase systems. It connects via a bolt-on method and supports an operating frequency range of 50/60 Hz. The switching is performed manually, and the breaker is UL and CSA certified.
Eaton Cutler-Hammer / PLCs / QuickLag
This circuit breaker operates at a voltage rating of 120/240 V and supports wire sizes ranging from #14 to 4 AWG. It features a connection type that utilizes bolt-on technology and has an impressive interrupt rating of 22 kAIC, making it suitable for various applications. Designed for installations
Eaton Cutler-Hammer / PLCs / QuickLag
This circuit breaker supports bolt-on mounting for straightforward installation. It has a significant interrupting capacity rated at 22 kAIC. The trip type is non-interchangeable, and it meets HACR ratings. Certified by UL and CSA, this product is dependable in residential and commercial application
Eaton Cutler-Hammer / PLCs / QuickLag
As a single-pole circuit breaker, the QBHCAF1015 is rated for an interrupt capacity of 22 KAIC. It incorporates thermal magnetic protection and offers functions for both long-time and instantaneous tripping. This device can effectively operate in environments with up to 80% humidity and is designed
Eaton Cutler-Hammer / PLCs / QuickLag
This thermal-magnetic breaker features a fixed trip unit and is configured with two poles. It withstands a dielectric voltage of 250 VAC and provides a maximum interrupting capacity of 22 kA. The device is rated for a system frequency of 60 Hz and designed with screw connection methods for installat
Eaton Cutler-Hammer / PLCs / QuickLag
This 1-pole breaker features a short-circuit interrupting rating of 10 kA. With a fault sensitivity of 5 mA, it is equipped with a thermal-magnetic trip mechanism. The unit utilizes a feed-through wiring configuration with a box lug connection and can be mounted on DIN rails.