714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The HFD2020V breaker features load side lugs for connection and is rated for an interrupting capacity of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC at 600 VAC. For DC applications, it offers an interrupting capacity of 22 kAIC at 250 VDC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This mechanism features a right-pole mounting position and is specified for operation within temperature limits of -20°C to 60°C. Additionally, it can be stored safely at temperatures ranging from -30°C to 70°C, and it supports non-condensing relative humidity levels between 0% and 95%. This device
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release mechanism features a pigtail lead connection and is designed for right-hand pole mounting. It functions efficiently within a frequency range of 50 to 60 Hz and operates optimally between temperatures of 0°C to 40°C.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This component offers right pole mounting and is compatible with F, J, and G-frame molded case circuit breakers. It operates efficiently in temperatures from -20°C to 60°C and can be stored in conditions ranging from -30°C to 70°C. The connection type is through pigtail leads, and it supports relati
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This component features pigtail leads for connection and is mounted on the left pole. It operates within a control voltage range of 110–127 V and is compatible with F frame sizes. Designed to perform within a temperature range of 0°C to 40°C, it also accommodates storage at similar conditions. This
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a two-pole design and uses a fixed thermal and magnetic trip mechanism. It has an interrupting capacity of 18 kAIC at 240 VAC and 14 kAIC at both 480 VAC and 600 VAC, providing robust thermal protection. The breaker is housed in an F frame type and weighs 3 lbs, suitabl
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles and operates in a three-phase configuration. The device incorporates thermal-magnetic trip technology, offering dependable protection against overloads and short circuits. It has impressive interrupting capacities, rated at 14 kAIC for both 480Y/277 VAC a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit employs fixed thermal and magnetic trip functions featuring long-time and instantaneous protection. The GD3045 has an interrupting capacity of 65 kAIC at 240 VAC and 22 kAIC at 480 VAC, allowing it to handle substantial fault currents safely. This breaker operates within a frequency range
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is designed for reliable protection with an interrupt rating of 65 kAIC at 240 VAC and 14 kAIC at 480Y/277 VAC. The fixed thermal and magnetic trip mechanism ensures precise performance, while the pressure-type terminals facilitate easy connections. It u
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Specifically, the 12NC1200 is compatible with several breaker frames including NC, NCA, NCG, NCGA, HNC, HNCA, HNCG, and HNCGA. It possesses a magnetic trip range from 2400 A to 9600 A and is compatible with both 2-pole and 3-pole configurations. The operating temperature for this device can range fr