197 results
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker operates at a frequency of 50/60 Hz and supports three poles for versatile applications. It features a substantial interrupt rating of 22 kA at 600Y/347V, ensuring effective management of fault conditions. Standard terminations are available for both the line side and load side,
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features a 3-pole configuration with a robust RG-frame style. Its interrupting capacities are rated at 125 kAIC for 240V AC and 65 kAIC for 480V AC, ensuring reliable protection against overloads and short circuits. It incorporates the Electronic Digitrip RMS 310 technology with
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This accessory is designed with three poles and fits within a J-frame size. It has impressive interrupting ratings of 25 kAIC at 480 VAC, 65 kAIC at 240 VAC, and 18 kAIC at 600 VAC. The operational frequency ranges from a minimum of 50 Hz to a maximum of 60 Hz.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This shunt trip kit operates with a voltage rating ranging from 110V AC to 240V AC and is designed for a frequency range of 50 to 60 Hz. It connects via pigtail leads and can be mounted on either the right or left pole. The kit functions effectively within temperature limits, from -20°C during opera
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features three poles and offers reliable operation in key applications. It has thermal-magnetic trip functionality and possesses significant interrupting capacity: 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC. The device is designed to handle demanding conditio
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This three-pole circuit breaker employs fixed thermal and magnetic trip types for protective measures. It showcases an interrupting capacity of 85 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 22 kAIC at 600Y/347 VAC, making it robust under fault conditions. The operational frequency range is between 50
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This three-pole circuit breaker supports frequencies from 50 Hz to 60 Hz. Its interrupting capacity varies by voltage: 125 kAIC at 240 VAC, 65 kAIC at 480 VAC, and between 35 kAIC to 50 kAIC at 600 VAC. The device utilizes an Electronic Digitrip 310 RMS for advanced trip functions, including Long-Ti
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This breaker operates across a voltage range of 600 V to 690 V AC and has impressive interrupting capacities, rated at 125 kAIC for 240V AC, 65 kAIC for 480V AC, and between 35 kAIC and 50 kAIC for 600V AC. It includes trip functions for long-time, short-time, and ground fault protection. The device
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker offers a robust interrupting capacity, rated at 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. Weighing 16 lbs, it is equipped with line and load terminal types to facilitate various installation needs.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker includes both fixed thermal and adjustable magnetic trip types, enhancing its performance across diverse electrical loads. Rated for a frequency range from 50 Hz to 60 Hz, it possesses substantial interrupting capacities of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC at