CHB360

CHB360

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features three poles and is equipped with bolt-on mounting for easy installation. It connects via lugs on the load side and uses a bolt-on connection for the line side. The CHB360 has an interrupting rating of 10 kiloamperes at 240 Volts AC and meets CSA, CE, and UL compliance s

Available
CHB340

CHB340

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker includes three poles, making it suitable for three-phase applications. It has an interrupt rating of 10 KAIC and accommodates wire sizes from #8 to #4 AWG. The operational temperature range for the CHB340 spans from 0°C to 40°C, and the same range applies for storage conditions.

In Stock Ships Tomorrow
CHB220

CHB220

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker consists of two poles and functions in a single-phase configuration. The CHB220 has a bolt-on connection type, allowing for robust attachment. Its screw/lug terminals can accommodate wire sizes ranging from 14 to 8 AWG.

In Stock Ships Today
CH260EPD

CH260EPD

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Featuring a dual-pole configuration, the CH260EPD has an impressive short circuit rating of 10 kAIC. It supports wire sizes from #14 to #6 AWG copper and can be mounted via a plug-in style. The breaker operates effectively at system frequencies of 50/60 Hz and is rated for a maximum ambient temperat

Call
CHN230GF

CHN230GF

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This GFCI breaker features a two-pole configuration and utilizes a thermal magnetic tripping mechanism, with a ground fault trip level set at 5 mA. It has a short-circuit rating of 10 kAIC, accommodating standard circuit protection needs. It connects via a plug-in method and is compatible with panel

Call
CHB320

CHB320

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker includes three poles and can handle wire sizes ranging from #14 to #8 AWG. It features an interrupt rating of 10 KAIC, ensuring reliable performance under fault conditions. This device operates safely at temperatures ranging from 0°C to 40°C and can be stored under the same temp

In Stock Ships Today
CHB2110

CHB2110

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This thermal magnetic circuit breaker consists of two poles, designed to manage long-time and instantaneous trips. Featuring a bolt-on connection type, its effective operation is guaranteed at a humidity level of 80% non-condensing. It is suitable for installation at altitudes of up to 1000 meters a

In Stock Ships Tomorrow
CHF120ST

CHF120ST

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker features a single pole configuration and is designed for 1-phase applications. It has a thermal magnetic protection system with long-time and instantaneous trip functions. The unit is rated with an interrupt capacity of 10 KAIC and utilizes a plug-in connection method. The CH fr

Call
CH215GFT

CH215GFT

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

This circuit breaker comprises two poles and provides thermal magnetic protection. It supports wire sizes ranging from #14 to #4 AWG and is rated for an interrupt capacity of 10 KAIC. The common trip type allows for simultaneous tripping of both poles during fault conditions.

Call
CH3090

CH3090

Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers

Incorporating a common breaker trip type and thermal-magnetic functions, the CH3090 features three poles. It offers an interrupt rating of 10 kAIC, ensuring reliability during overcurrent events. The unit is configured for bolt-on connections and is intended for mounting within loadcenters, conformi

In Stock Ships Today