365 results
GE Fanuc Emerson / Spectra
Designed in compliance with the Spectra series, this circuit breaker has three poles and provides an interrupt rating of 18 kAIC at 480 V. It features a bolt-on connection type for secure installation and utilizes both long-time and instantaneous trip methods to ensure reliable protection. The E150
GE Fanuc Emerson / Spectra
This rating plug is intended for 3-pole breakers and connects directly into the breaker trip unit socket. It complies with a voltage class of 600 V AC and functions within a frequency range of 50 to 60 Hz. The insulation category is classified as Class II, and it exhibits a dielectric strength of 22
GE Fanuc Emerson / Spectra
This circuit breaker operates with a single-pole configuration suitable for single-phase systems. It provides long-time and instantaneous trip functions. The unit is bolted onto connections and has a significant AIC rating of 65 kA, which assures effective interruption during fault conditions. The h
GE Fanuc Emerson / Spectra
The TEY250 is equipped with a thermal-magnetic trip type for reliable performance, and supports a frequency range of 50/60 Hz. With an interrupting capacity of 14 kA at 480 volts AC and an alternative rating of 65 kA at 240 volts AC, it ensures robust protection against overload conditions. This mod
GE Fanuc Emerson / Spectra
Designed to handle up to 60 Amps, this circuit breaker has a maximum interrupting capacity of 25kA. It is suitable for 50/60 Hz applications and supports load side lug type terminal connections. The TEYD3060B features a pivot/toggle handle lever for easy operation.
GE Fanuc Emerson / Spectra
This circuit breaker features two poles and is equipped with trip functions, including long-time, short-time, and instantaneous. The device has an interrupting capacity of 25 kA at 480V and utilizes lug connections. Designed for panel mounting, it allows for straightforward integration into electric
GE Fanuc Emerson / Spectra
This two-pole circuit breaker features a fixed trip type with thermal magnetic protection. It is compatible with both solid and stranded conductors. The unit accommodates a wire size range of 14 to 10 AWG, making it versatile for different installation needs.
GE Fanuc Emerson / Spectra
Designed to support a LI trip function, this circuit breaker maintains a standard continuous current rating and features fixed long-time protection. It can be installed at an altitude of up to 1000 meters and supports reverse feed functionality with appropriate wire sizes ranging from 4 to 2/10.
GE Fanuc Emerson / Spectra
This bus plug features three poles and is designed for plug-in mounting to the Spectra SL busway. It has an interrupt rating of 200 kA at 240 VAC and uses R-class fuses. A ground tab is also included for enhanced safety. The unit complies with NEMA 1 enclosure standards, making it suitable for indoo