966 results
Honeywell / Micro Switch
This limit switch features a roller arm actuator style and a double-pole double-throw (DPDT) contact configuration. It operates within a wide temperature range, from -20°C to 105°C, and is rated for a 10.0 A current. With a NEMA rating covering 1, 3, 4, 6, 6P, 12, and 13, it is suitable for multiple
Honeywell / Model 41 Series
Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above
Honeywell / Sensepoint XCD
This flame detector weighs 1.05 lb and operates at a nominal voltage of 24 VDC with a current rating of 25 mA. Its IP65 rating provides protection against dust and water. The dual-sensor technology employs Ultraviolet/Infrared (UV/IR) sensing, ensuring a detection range of up to 80 ft (25 m). Its co
Honeywell / Sensepoint XCD
This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid
Honeywell / Sensepoint XCD
This gas detector functions within a voltage range of 16 to 32 VDC and operates efficiently between -40°C and +65°C. It has an IP66 rating, ensuring robust protection against dust and water ingress. Features include a current output range of 4-20 mA, capable of sinking or sourcing current and provid
Honeywell / XNX Universal Transmitters
This surface-mounted unit is constructed from painted LM25 aluminum and features an LCD display for easy readability. It includes multiple digital communication options such as HART, MODBUS, and FOUNDATION H1 Fieldbus. The unit has an isolated 4-20 mA analog output for HART communication and a digit
Honeywell / Sensepoint XCD
This replacement cartridge provides methane detection with a range from 0 to 100% LEL. It features a robust 316 stainless steel housing for durability and is rated IP66 for protection against dust and water. The device operates between 12 to 32 VDC and maintains function across a significant pressur
Honeywell / Sensepoint XCD
As a component aimed at detecting oxygen, the SPXCDTMO12 supports a response time of 30 seconds. The device utilizes a digital communication protocol of RS-485 Modbus RTU and provides an analog output of 4–20 mA via a 3-wire connection. Additionally, it is rated IP66 for protection against dust and
Honeywell / Other
This electrode supports a range of measuring applications and is classified as a spare part or accessory. It operates effectively in temperatures from -5 degrees Celsius up to 110 degrees Celsius and can tolerate relative humidity levels of up to 80% without condensation. Additionally, it is rated f