966 results
Honeywell / V5055
This gas valve body operates effectively at pressures up to 15 psi and supports a minimum temperature of -40°C, extending to a maximum of 66°C. Equipped with a 1/4-inch spade terminal for electrical connections, it is rated for 120V AC and 60 Hz frequency, suitable for various heating systems.
Honeywell / SLATE
Part of the SLATE series, the R8001M1150 operates within a temperature range from -28 °C to 70 °C. It supports a communication protocol of RS-485 and features a NEMA 1 enclosure rating for protection. The actuator operates effectively at relative humidity levels of 0 to 99% and is rated for temperat
Honeywell / V8944
This gas valve is designed for 1-1/4 inch piping and supports an operating pressure of 1/2 psi. It utilizes a rapid opening characteristic for prompt gas flow management. The valve, constructed from die-cast aluminum, can be mounted horizontally for optimal performance.
Honeywell / IFD Series
This module is capable of functioning within a temperature range of -20 °C to 60 °C. It has a weight of 1.5 lbs and supports an input voltage frequency of 50/60 Hz. With a designed lifetime of 250,000 operating cycles for the control unit and 1,000 for the reset/mains buttons, it ensures long-term r
Honeywell / Micro Switch
This limit switch is equipped with a side rotary actuator and employs maintained switch action. It has a contact configuration of SPDT x4, supporting current ratings up to 15 A and voltage ratings of 120/240/480 VAC. With an IP66 rating, it is protected against dust and water, ensuring reliability i
Honeywell / Micro Switch
With a solid aluminum housing coated with electrostatic epoxy, the 21CX4 provides durability. The switch is configured with four SPDT contacts, offering configuration as 1NC and 1NO per switch, all encompassing momentary action. It allows for flexible conduit connection with a 3/4-14 NPT termination
Honeywell / Model 41 Series
Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / Sensepoint XCD
This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid