966 results
Honeywell / Searchpoint Optima Plus
The 2108N4100H gas detector features a 3/4-inch NPT threaded spigot for easy installation. It operates effectively within a temperature range of -40 to 65 degrees Celsius for both storage and operational conditions. The device supports HART communication with a 4 to 20 mA output, and it includes adv
Honeywell / Sensepoint XCD
This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an
Honeywell / Sensepoint XCD
The SPXCDULNFX flammable gas detector features an IP66 rating and can function within a temperature span of -40°C to 65°C. The device supports a continuous humidity range of 20-90% RH and intermittent levels of 0-99% RH. It utilizes a catalytic bead sensor capable of detecting methane concentrations
Honeywell / GR Series
This graphic recorder is designed with numerous input slots, including four that accommodate 8 analog inputs each and one slot that provides options for relay inputs, digital inputs, or configurable outputs. The operational specifications include a power rating of 90-240V AC and an input frequency o
Honeywell / HercuLine 10260
This actuator operates on a power supply of 120 VAC and utilizes a single-phase configuration, making it adaptable for standard applications. With an operating temperature range from -30 °C to 85 °C, it is suitable for various environments. It includes features such as a dual 1000 Ohm film potentiom
Honeywell / HercuLine 2001
This actuator operates on a single-phase power supply of 100 to 130 VAC and features a rotation of 90 degrees, with a response time of 15 seconds at 60 Hz. It offers multiple analog input and output signals for enhanced flexibility. Furthermore, the actuator includes programmable relay outputs and a
Honeywell / HercuLine 2001
This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches
Honeywell / SmartLine
Operating with a maximum turndown ratio of 100:1, this transmitter has an upper range limit of 100 in H2O (7 mbar) and a lower range limit of -100 in H2O (-7 mbar). The diaphragm and process head are both made from durable 316 stainless steel, ensuring longevity and reliability. The fill fluid consi
Honeywell / UDA2182
This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35