Honeywell / 7800 Series
This relay control module can establish both pilot and main flames in periods of either 3 or 5 seconds. It features an early spark termination option set to 5 seconds and includes post-purge timing of 30 seconds. The device functions effectively across a broad temperature range from -40°C to 60°C.
Honeywell / SLATE
This base module, weighing 2 lbs, operates between specified frequencies of 50 Hz and 60 Hz, making it suitable for a wide range of applications. It is built to function optimally in environments with a temperature range from -29°C to 66°C, and can be stored safely at temperatures as low as -40°C. T
Honeywell / V4055
This power gas valve actuator functions seamlessly at a rated frequency of 60 Hz and is suitable for operating pressures of either 15 or 25 psi. It features a direct-mount valve bonnet connection and has a proof-of-closure switch integrated into its design. Operating effectively between ambient temp
Honeywell / V4055
This actuator provides a consistent opening time of 13 seconds while ensuring a fast closing time of one second or less. It operates effectively at an ambient temperature range from -23°C to 70°C and handles a pressure of 5 PSI. The NEMA 1 enclosure is rated IP30, offering a good level of protection
Honeywell / 7800 Series
Featuring a pilot flame establishing period of either 4 or 10 seconds, this relay control module ensures reliable performance in on-off applications. It supports dynamic airflow switch checks and functions efficiently within a temperature range of -40°C to 60°C.
Honeywell / V4055
This gas valve actuator provides an opening timing of 13 seconds and can close in 1 second or less. It is intended for use with V5055 valve bodies and includes a damper shaft. The operational range supports pressures of 15 psi and 25 psi, suitable for diverse applications. The actuator functions wit
Honeywell / IFD Series
This burner control unit has an IP54 rating, indicating it is protected against dust and water splashes. It functions within an operating temperature range from -20°C to 60°C and weighs 1.34 lbs. The device can be mounted using a DIN rail or M5 screw, which provides installation flexibility.
Honeywell / Sensepoint XCD
This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid