Honeywell / V5011
This 2-way globe valve has a flow capacity of 46.8 Cv and can withstand a close-off pressure up to 240 psi. It features female NPT connections, along with stainless steel components for durability. The valve operates efficiently in fluid temperatures ranging from 2°C to 120°C.
Honeywell / VBN Series
Engineered with a 2-way straight-through body pattern, this valve offers a flow capacity of 124 Cv and operates effectively under a close-off pressure of 100 psi. It withstands body pressure up to 360 psi and is suitable for fluid temperatures ranging from -30° to 121°C.
Honeywell / 7800 Series
This burner control features a weight of 1 lb. It establishes the pilot flame within a time frame of 4 to 10 seconds, while the main flame takes 10 to 15 seconds to stabilize. Operating at a frequency between 50 Hz and 60 Hz, this device is compatible with multiple flame amplifiers, including models
Honeywell / V5055
This product is classified as a high-pressure on-off safety shutoff valve and is constructed from die-cast aluminum. It offers a maximum body rating of 75 psi and can accommodate an operating pressure differential of up to 15 psi. With a valve capacity of 5230 cf/hr, it connects with a 3-inch NPT pi
Honeywell / V8944
The V8944B1035 operates on natural gas and is rated for 24 VAC with a frequency of 50/60 Hz. It can function effectively in ambient temperatures ranging from -40°C to 66°C and is constructed from durable die-cast aluminum. This valve features a maximum operating pressure of 0.5 psi (3.4 kPa) and an
Honeywell / 7800 Series
This relay control module can establish both pilot and main flames in periods of either 3 or 5 seconds. It features an early spark termination option set to 5 seconds and includes post-purge timing of 30 seconds. The device functions effectively across a broad temperature range from -40°C to 60°C.
Honeywell / 7800 Series
This primary safety control relay operates effectively in a temperature range from -40°C to 60°C and can endure vibration levels of 0.5G. It has a color-coded label in green for identification and supports a flame signal strength range of 0 to 5.0V DC. With a maximum relative humidity rating of 85%
Honeywell / V8944
This gas valve is designed for 1-1/4 inch piping and supports an operating pressure of 1/2 psi. It utilizes a rapid opening characteristic for prompt gas flow management. The valve, constructed from die-cast aluminum, can be mounted horizontally for optimal performance.
Honeywell / IFD Series
This burner control unit has an IP54 rating, indicating it is protected against dust and water splashes. It functions within an operating temperature range from -20°C to 60°C and weighs 1.34 lbs. The device can be mounted using a DIN rail or M5 screw, which provides installation flexibility.
Honeywell / IFD Series
This burner control unit offers a maximum valve output current of 1 A and an ignition output current of up to 2 Amps at a power factor of 0.2. It features an operational temperature range of -20°C to 60°C and is housed in an enclosure rated at IP 54 for protection against dust and water. The unit ca