Honeywell / 7800 Series
This device is designed for mounting as a plug-in module on Q7800A/Q7800B wiring subbases. It supports interrupted pilot types and has a main flame establishment duration of 10 seconds and a postpurge timing of 15 seconds. The operational temperature range extends from -40°C to a maximum of 60°C, ac
Honeywell / 7800 Series
This primary safety control relay operates effectively in a temperature range from -40°C to 60°C and can endure vibration levels of 0.5G. It has a color-coded label in green for identification and supports a flame signal strength range of 0 to 5.0V DC. With a maximum relative humidity rating of 85%
Honeywell / V4055
This actuator provides a consistent opening time of 13 seconds while ensuring a fast closing time of one second or less. It operates effectively at an ambient temperature range from -23°C to 70°C and handles a pressure of 5 PSI. The NEMA 1 enclosure is rated IP30, offering a good level of protection
Honeywell / V8944
This gas valve is designed for 1-1/4 inch piping and supports an operating pressure of 1/2 psi. It utilizes a rapid opening characteristic for prompt gas flow management. The valve, constructed from die-cast aluminum, can be mounted horizontally for optimal performance.
Honeywell / Micro Switch
This limit switch is engineered for high reliability, featuring a dual SPDT contact configuration and hermetically-sealed basic switches. It accommodates a voltage rating of 125 VAC and 28 VDC, with a maximum current rating of 1 Amp for AC and 5 Amps for DC applications.
Honeywell / Micro Switch
This limit switch weighs 2.45 lbs and utilizes a side-rotary actuator type with an adjustable hinge rod lever. The SPDT contact configuration is designed for momentary action. Sealed against oils, water, and dust, the switch ensures reliability in challenging conditions.
Honeywell / Searchpoint Optima Plus
This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio
Honeywell / Sensepoint XCD
This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an
Honeywell / Other
This UV flame detector weighs 6 lbs and has a robust NEMA 4 rating for environmental protection. It is effective in temperatures ranging from -40°C to 79°C, accommodating various operational situations. This device includes a self-check function where an oscillating shutter interrupts the UV signal
Honeywell / Other
This gas valve features a maximum operating pressure of 0.5 psi (3.4 kPa) and regulates pressure through two stages, accommodating low-fire and high-fire conditions. It comes equipped with an NPT threaded pipe connection and is designed for 1-1/2 inch pipe sizes. The opening cycle of the valve varie