966 results
Honeywell / SmartVFD HVAC
This variable frequency drive has a continuous output current of 5.6 A. It features a NEMA 1 enclosure type and incorporates communication protocols such as BACnet, Modbus RTU, and N2 (RS485). It includes 6 digital inputs, 2 analog inputs, and 3 relay outputs for flexible control options.
Honeywell / V5011
This 2-way globe valve has a flow capacity of 46.8 Cv and can withstand a close-off pressure up to 240 psi. It features female NPT connections, along with stainless steel components for durability. The valve operates efficiently in fluid temperatures ranging from 2°C to 120°C.
Honeywell / 7800 Series
This model supports a pilot flame establishing period ranging from 4 to 10 seconds and a main flame establishing period of 10 to 15 seconds. It operates effectively at a rated voltage of 120 VAC and accommodates a frequency range of 50 to 60 Hz. Operating conditions are suitable in temperatures from
Honeywell / 7800 Series
This diagnostic tester supports an input voltage frequency of 50/60 Hz. It works within a temperature range from -18°C to 49°C during operation, while it can withstand storage conditions between -34.5°C and 65°C. The unit dissipates 20 watts of power and includes a 1.0A (3AG) fuse for protection. It
Honeywell / V4055
This actuator operates with a voltage frequency of 60 Hz and is capable of functioning in ambient temperatures between -40°C and 66°C. It is rated IP54, ensuring protection against dust and water ingress. The actuator can handle maximum operating pressures of either 15 or 25 psi and features an open
Honeywell / SLATE
This actuator supports a positioning resolution of 900 distinct positions within a 90° range. It features a travel time of 15 seconds for a full 90° stroke. Communication is facilitated via an isolated Modbus RS-485 protocol. With an operating temperature range from -40°C to 70°C, it is suitable for
Honeywell / 7800 Series
This relay control module can establish both pilot and main flames in periods of either 3 or 5 seconds. It features an early spark termination option set to 5 seconds and includes post-purge timing of 30 seconds. The device functions effectively across a broad temperature range from -40°C to 60°C.
Honeywell / V8944
This gas valve is designed for 1-1/4 inch piping and supports an operating pressure of 1/2 psi. It utilizes a rapid opening characteristic for prompt gas flow management. The valve, constructed from die-cast aluminum, can be mounted horizontally for optimal performance.
Honeywell / V8944
Designed for two-stage pressure regulation, this diaphragm gas valve features compatibility with natural gas. It operates at a rated voltage of 24 VAC across frequencies from 50 Hz to 60 Hz, maintaining an operating pressure of 1/2 psi. The device is constructed from die-cast aluminum and includes c
Honeywell / V8944
This valve is a rapid-opening diaphragm type, which features an impressive flow capacity ranging from 780 to 2300 CFH. It operates at a frequency of 60 Hz and consumes 12.4 VA of power. The device is constructed from die-cast aluminum and has opening and closing times of less than 6 seconds and 2 se