Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

2001-200-090-126-200-00-011000-1-0- 0

2001-200-090-126-200-00-011000-1-0- 0

Honeywell / HercuLine 2001

This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20

Call
DR45A1-1000-00-000-0-100000-0

DR45A1-1000-00-000-0-100000-0

Honeywell / DR4500

This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with

Call
UDA2182-CC1-CC2-NN-N-0000-EE

UDA2182-CC1-CC2-NN-N-0000-EE

Honeywell / UDA2182

Operating within a temperature span of 0°C to 60°C, the UDA2182 analyzer is suited for various settings. It features a graphical LCD equipped with a white LED backlight for improved visibility. A 10-button membrane keypad facilitates user interaction, while the unit is constructed from durable GE Va

Call
STT850-S-0-A-CDE-11S-A-30A6-00-0000

STT850-S-0-A-CDE-11S-A-30A6-00-0000

Honeywell / SmartLine

Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp

Call
STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

Honeywell / SmartLine

This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs

Call
STT750-S-0-A-GH0-11C-B-11A0-F1-0000

STT750-S-0-A-GH0-11C-B-11A0-F1-0000

Honeywell / SmartLine

This temperature transmitter supports a single universal input and provides no digital output or indicator. Its operating range spans from -40 °C to 85 °C and is encased in durable 316 stainless steel for strong protection. The device includes lighting protection and utilizes a flat pipe mounting br

Call
DC3500-C0-0J20-133-00000-E0-0

DC3500-C0-0J20-133-00000-E0-0

Honeywell / UDC3500

This controller operates at power compatibility levels between 90 and 264V AC and allows output currents of 4 to 20 mA and 0 to 20 mA. It features two loops of control along with internal cascade capabilities. While relay outputs are not available, it supports multiple input types including TC, RTD,

Call
2000-100-150-126-000-20-000000-0-0-0

2000-100-150-126-000-20-000000-0-0-0

Honeywell / HercuLine 2000

This actuator operates on a single-phase system with an input frequency of 60 Hz. It includes two auxiliary switches for added functionality and handles analog input signals using a 3-wire drive for up and down control. Designed for various environmental conditions, it operates effectively in humidi

Call
2000-200-150-126-015-00-000000-0-0-00

2000-200-150-126-015-00-000000-0-0-00

Honeywell / HercuLine 2000

This actuator operates on a single-phase power supply of 100-130 VAC and has an input frequency of 60 Hz. It features a 3-wire drive for analog input operation and provides dual analog output signals at 1000 Ohms over its full rotation. The actuator rotates counterclockwise when the signal increases

Call
DC3500-0E-3000-211-00000-E0-0

DC3500-0E-3000-211-00000-E0-0

Honeywell / UDC3500

This digital controller supports a wide range of inputs including TC, RTD, mV, as well as voltage and current signals. It operates with relay outputs configured as three Form C E-M Relays with a rating of 5 Amps each. Designed for a single control loop, it features a power compatibility that spans f

Call
Showing 281-290 of 966 results