966 results
Honeywell / DR4500
This circular chart recorder features a 12-inch diameter chart and supports input channels for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operational temperature range spans from 0 °C to 55 °C, allowing it to function effectively in various environments. It is also designed for multiple
Honeywell / HercuLine 2001
This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20
Honeywell / DR4500
This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with
Honeywell / UDA2182
Operating within a temperature span of 0°C to 60°C, the UDA2182 analyzer is suited for various settings. It features a graphical LCD equipped with a white LED backlight for improved visibility. A 10-button membrane keypad facilitates user interaction, while the unit is constructed from durable GE Va
Honeywell / SmartLine
Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp
Honeywell / SmartLine
This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs
Honeywell / SmartLine
This temperature transmitter supports a single universal input and provides no digital output or indicator. Its operating range spans from -40 °C to 85 °C and is encased in durable 316 stainless steel for strong protection. The device includes lighting protection and utilizes a flat pipe mounting br
Honeywell / UDC3500
This controller operates at power compatibility levels between 90 and 264V AC and allows output currents of 4 to 20 mA and 0 to 20 mA. It features two loops of control along with internal cascade capabilities. While relay outputs are not available, it supports multiple input types including TC, RTD,
Honeywell / HercuLine 2000
This actuator operates on a single-phase system with an input frequency of 60 Hz. It includes two auxiliary switches for added functionality and handles analog input signals using a 3-wire drive for up and down control. Designed for various environmental conditions, it operates effectively in humidi
Honeywell / HercuLine 2000
This actuator operates on a single-phase power supply of 100-130 VAC and has an input frequency of 60 Hz. It features a 3-wire drive for analog input operation and provides dual analog output signals at 1000 Ohms over its full rotation. The actuator rotates counterclockwise when the signal increases