967 results
Honeywell / Other
Designed for compatibility, the S963B1136 works seamlessly with W973 logic panels and W975 satellite sequencers. It operates within a range of heat/cool ramp signal voltages from 2V DC to 16.6V DC, ensuring flexibility in applications requiring modulation of these signals.
Honeywell / Other
This gas detector has an operating voltage of 24 VDC nominal, with a flexible range between 18 and 32 VDC. The unit performs accurately within a wide operating temperature spectrum of -40°C to +65°C, ensuring functionality in harsh conditions. Its signal output is configured for a 4–20 mA range, acc
Honeywell / V5055
The V5055D1032 operates under a maximum rated pressure of 75 PSI with the ability to handle a pressure differential of up to 15 PSI using a standard actuator and 45 PSI with a high-pressure actuator. It is capable of functioning in a broad ambient temperature range, from -40 °C to 66 °C, and demonst
Honeywell / HercuLine 2002
This actuator operates on a single-phase power supply ranging from 100 to 130 VAC, ensuring compatibility with standard power systems. It has a rotation speed of 15 seconds at 60 Hz and can rotate up to 90 degrees. The product features non-contact position sensing and is capable of receiving analog
Honeywell / DR4500
This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i
Honeywell / DR4500
This circular chart recorder features multiple inputs including T/C, RTD, Radiamatic, and signals of mV, 0–5V, and 4–20mA. It includes one control output with setpoint programming and is outfitted with a standard pen. The device has a gray door with a glass window and utilizes a standard latch mecha
Honeywell / HercuLine 2000
This actuator operates on a single-phase power supply of 100-130 VAC and has an input frequency of 60 Hz. It features a 3-wire drive for analog input operation and provides dual analog output signals at 1000 Ohms over its full rotation. The actuator rotates counterclockwise when the signal increases
Honeywell / HercuLine 2000
This actuator operates on a single-phase power supply ranging from 100 to 130 VAC and has an input frequency of 60 Hz. It employs a 3-wire drive system for upward and downward movement, facilitating user-friendly analog input signals. The actuator also provides two 1000-ohm analog output signals acr
Honeywell / UDC3500
This digital controller features a single loop of control and provides multiple input types, including TC, RTD, mV, 0-5V, and 1-5V signals as well as 0-20mA and 4-20mA inputs. Equipped with three form C E-M relays rated for 5 Amps, it offers reliable switching capabilities. Additionally, the system
Honeywell / UDC3500
As part of the UDC3500 series, this digital controller supports a single control loop and features three Form C E-M relay outputs rated at 5 amps. The unit operates effectively across ambient temperatures from 15 °C to 55 °C and is compliant with CE standards, making it suitable for various environm