STT830-0TB-00-SNE0-H02S-R2UD-C00SR080-00-000

STT830-0TB-00-SNE0-H02S-R2UD-C00SR080-00-000

Honeywell / SmartLine

This temperature probe assembly includes a 3-wire IEC Pt100 sensor in an ungrounded configuration. It operates effectively within temperature ranges of 0 to 40 degrees Celsius and supports storage conditions from 0 to 50 degrees Celsius. The assembly utilizes a threaded bar stock for the thermowell

Call
DC2800-CE-0F0-200-000-00-0

DC2800-CE-0F0-200-000-00-0

Honeywell / UDC2800

Incorporating a current output rated at either 4 to 20 mA or 0 to 20 mA, this device also features a 5 Amp Form C electro-mechanical relay with alarm capabilities. Operating at a humidity level of 90% (non-condensing), it performs effectively at an altitude of 2000 meters, withstanding vibration fre

Call
DC2800-EE-0F0-100-100-00-0

DC2800-EE-0F0-100-100-00-0

Honeywell / UDC2800

In the UDC2800 series, the DC2800-EE-0F0-100-100-00-0 features various control outputs, including an electro-mechanical relay. With a 5 Amp Form C relay and alarm output, it also supports temperature input through TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. This unit is designed for

Call
DC1201-2-2-1-3-1-0-0-0

DC1201-2-2-1-3-1-0-0-0

Honeywell / UDC1200

This universal digital controller supports field-selectable inputs and processes data at a sampling rate of 4 samples per second. Outputs include SSR drivers and an electromechanical SPDT relay. Designed to operate within a wide voltage range of 90 to 264 VAC, it functions optimally across frequenci

Call
DC2800-E0-1L0-100-200-00-0

DC2800-E0-1L0-100-200-00-0

Honeywell / UDC2800

This universal digital controller focuses on delivering reliable performance with an input capacity for thermocouples, RTDs, and millivolt signals, alongside voltage inputs of 0-5V, 1-5V, and 0-10V. It operates efficiently between 0°C to 55°C and manages relative humidity conditions from 5% to 90%.

Call
30754975-503

30754975-503

Honeywell / DR4500

This servo plate assembly operates effectively within a temperature range that spans from 32°F to 131°F. It supports ambient humidity levels between 5% and 90% without condensation. The unit can withstand a vibration frequency of 0 to 200 Hertz and features a mechanical shock endurance of up to 5 g

Call
DC2800-EB-0L0-200-200-00-0

DC2800-EB-0L0-200-200-00-0

Honeywell / UDC2800

This UDC2800 controller provides one electro-mechanical relay output rated at 5 Amp (Form C) and an additional alarm relay. It accommodates a variety of input types, including thermocouples (TC), RTDs, and multiple voltage and current input signals. Designed to function between 0°C and 55°C, it is c

Call
DC1201-7-1-0-2-1-0-0-0

DC1201-7-1-0-2-1-0-0-0

Honeywell / UDC1200

This universal digital controller provides field-selectable universal input types with a sampling rate of 4 samples per second. Its outputs include a configurable linear DC output and an electromechanical SPDT relay. The device operates between 0 °C and +55 °C, with a universal power supply acceptin

Call
50009551-501

50009551-501

Honeywell / UDA2182

This preamp input card is designed primarily to connect seamlessly with UDA2181 channel input connections, accommodating both channel 1 and channel 2 inputs. It operates effectively within a temperature span of 32°F to 140°F and can be stored between -22°F to 158°F. The device maintains operational

Call
DC2800-CB-0S0-200-100-00-0

DC2800-CB-0S0-200-100-00-0

Honeywell / UDC2800

This universal digital controller accommodates various input types, including TC, RTD, and millivolt signals as well as voltage and current inputs. It operates within a temperature range of 0°C to 55°C and provides a solution for managing humidity levels from 5% to 90% (non-condensing). A significan

Call