967 results
Honeywell / DR4500
This circular chart recorder features multiple inputs including T/C, RTD, Radiamatic, and signals of mV, 0–5V, and 4–20mA. It includes one control output with setpoint programming and is outfitted with a standard pen. The device has a gray door with a glass window and utilizes a standard latch mecha
Honeywell / HercuLine 2000
This actuator operates on a single-phase power supply of 100-130 VAC and has an input frequency of 60 Hz. It features a 3-wire drive for analog input operation and provides dual analog output signals at 1000 Ohms over its full rotation. The actuator rotates counterclockwise when the signal increases
Honeywell / HercuLine 2000
This actuator operates on an input frequency of 60 Hz and requires a single-phase power supply of 100-130 VAC. It weighs 25 lbs and does not include advanced electronic components in its motor selection. The unit features dual 1000-ohm analog output signals while utilizing a 3-wire drive for up/down
Honeywell / DR4500
This main processor board operates efficiently between 0 and 40 degrees Celsius. For storage, it can withstand temperatures ranging from 0 to 50 degrees Celsius. This unit is rated for a maximum operating and storage relative humidity of 80% without condensation. It can be utilized effectively at al
Honeywell / UDC3500
This digital controller features a single loop of control and provides multiple input types, including TC, RTD, mV, 0-5V, and 1-5V signals as well as 0-20mA and 4-20mA inputs. Equipped with three form C E-M relays rated for 5 Amps, it offers reliable switching capabilities. Additionally, the system
Honeywell / UDC3500
As part of the UDC3500 series, this digital controller supports a single control loop and features three Form C E-M relay outputs rated at 5 amps. The unit operates effectively across ambient temperatures from 15 °C to 55 °C and is compliant with CE standards, making it suitable for various environm
Honeywell / UDC3500
This model features capabilities for two control loops and an internal cascade for advanced process management. It includes three Form C relays rated at 5 amps. With input options for thermocouples, RTDs, and various voltage and current signals, this device adapts to numerous sensing requirements. T
Honeywell / UDC2800
The digital controller facilitates inputs from various sensors, including TC, RTD, and mV types, as well as a range of voltage and current inputs. Designed for efficient operation, it can accommodate a power supply of 100 to 240 VAC and functions effectively in ambient temperatures of 0 to 55 °C. It
Honeywell / UDC2800
This digital controller handles outputs including a 4 to 20 mA or 0 to 20 mA current output, as well as a 5-amp Form C electromechanical relay with alarm functions. It supports a wide range of input signals such as TC, RTD, and various voltages. The controller is suitable for installations at altitu
Honeywell / UDC2800
This digital controller supports multiple thermocouple (TC), resistance temperature detector (RTD), and millivolt inputs, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It incorporates a flexible current output capability of either 4 to 20 mA or 0 to 20 mA. The controller also hosts one Form C