Honeywell / 7800 Series
This relay control module is designed for primary control applications, supporting operational frequencies between 50 Hz and 60 Hz. It dissipates 10W of power and can withstand vibration resistance up to 0.5 G. The operating temperature range extends from -40 °C to 60 °C, and it can be stored at tem
Honeywell / Model 41 Series
This model features an excitation voltage of 10V DC and operates effectively in a temperature range from -54°C to 121°C. It is designed for both tension and compression operations and uses a durable housing made of 17-4PH stainless steel. The load cell accommodates a maximum relative humidity of 80%
Honeywell / Model 41 Series
This load cell features two diaphragms and outputs in both standard mV and voltage formats (4 to 20 mA and 0-5V DC, respectively). It offers accuracy at 0.10% and has infinite resolution, ensuring precise readings. The nominal bridge resistance is set at 350 Ohms, while operation can handle temperat
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / Sensepoint XCD
This transmitter features a 4-20 mA current output that can operate in either sink or source configurations. The kit includes a 705 catalytic bead combustible sensor, with a detection range of 0-100% LEL. It supports a maximum remote sensor distance of up to 30 m and can function within an operating
Honeywell / Sensepoint XCD
This detector features an IP66 rating, signifying its resilience against dust and water ingress. It operates efficiently in temperatures ranging from -40°C to 65°C and can be stored within a similar temperature range. Supporting humidity levels from 20-90% RH continuously, it also accommodates inter
Honeywell / Sensepoint XCD
This unit is rated IP66, allowing it to function effectively in harsh environments. The device operates within a temperature range of -40°C to 65°C and has a housing made of epoxy-painted LM25 aluminum alloy, ensuring durability. A maximum inrush current is specified at 800 mA at 24 VDC, with a 4-20
Honeywell / Sensepoint XCD
This module is designed to function efficiently across a wide operating temperature range from -40°C to 65°C. It features an IP66 rating, ensuring protection against dust and water ingress. The module includes three programmable relay outputs and communicates via an RS-485 Modbus RTU interface.
Honeywell / Other
Operating with two pipes, this humidistat features a throttling range from 3 to 15% RH. It consumes airflow at a rate of 0.011 scfm and maintains functionality under an operating pressure of 25 Psi. Its design allows it to work effectively across a temperature spectrum of 7 °C to 52 °C for operation