Honeywell / Sensepoint XCD
This transmitter features a 4-20 mA current output that can operate in either sink or source configurations. The kit includes a 705 catalytic bead combustible sensor, with a detection range of 0-100% LEL. It supports a maximum remote sensor distance of up to 30 m and can function within an operating
Honeywell / Sensepoint XCD
This detector features an IP66 rating, signifying its resilience against dust and water ingress. It operates efficiently in temperatures ranging from -40°C to 65°C and can be stored within a similar temperature range. Supporting humidity levels from 20-90% RH continuously, it also accommodates inter
Honeywell / Sensepoint XCD
This unit is rated IP66, allowing it to function effectively in harsh environments. The device operates within a temperature range of -40°C to 65°C and has a housing made of epoxy-painted LM25 aluminum alloy, ensuring durability. A maximum inrush current is specified at 800 mA at 24 VDC, with a 4-20
Honeywell / Sensepoint XCD
This module is designed to function efficiently across a wide operating temperature range from -40°C to 65°C. It features an IP66 rating, ensuring protection against dust and water ingress. The module includes three programmable relay outputs and communicates via an RS-485 Modbus RTU interface.
Honeywell / Other
This controller operates on a dual-pipe system and functions effectively with a liquid-filled remote bulb sensing element. With a maximum sensing element temperature of 110°C and a controller temperature limit of 66°C, it ensures reliable performance. The capillary length extends to 5 feet, facilita
Honeywell / Other
This device operates effectively with a reset pressure range of 1 to 15 psi and ensures safe operations at pressures up to 30 psi. Its control capability allows air velocity adjustments from 2.5 m/s to 17.8 m/s. It is designed to work with mainline air pressure of 18 psi, featuring remote sensor fun
Honeywell / Other
Operating with two pipes, this humidistat features a throttling range from 3 to 15% RH. It consumes airflow at a rate of 0.011 scfm and maintains functionality under an operating pressure of 25 Psi. Its design allows it to work effectively across a temperature spectrum of 7 °C to 52 °C for operation
Honeywell / Other
Equipped with two potentiometers, this unit features 4 test leadwires and can handle heat/cool ramp signals effectively. The device's voltage range for these signals extends from a minimum of 2V DC to a maximum of 16.6V DC. It operates properly in environments with relative humidity not exceeding 80
Honeywell / Other
The RP7517B1024 transducer ensures an output pressure range from 3 to 15 psi and can withstand maximum operating pressure of 30 psi. Rated for power consumption at 1.7 VA, it features a direct acting mechanism and uses screw terminals or lead wires for electrical connections. With operational temper
Honeywell / Other
This diaphragm gas valve boasts a 2-inch NPT pipe connection and is made from durable cast aluminum. It operates at an input voltage of 120 VAC and a frequency of 60 Hz. The opening and closing timing of this valve is 5 seconds and 2 seconds, respectively, and it operates safely at 1 PSI. A bleed ta