966 results
Honeywell / Micro Switch
This limit switch weighs 2.45 lbs and utilizes a side-rotary actuator type with an adjustable hinge rod lever. The SPDT contact configuration is designed for momentary action. Sealed against oils, water, and dust, the switch ensures reliability in challenging conditions.
Honeywell / Model 41 Series
Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / 301EM Series
This infrared gas detector efficiently measures hydrocarbons with a range of 0-100% LEL. It features an IP66/IP67 rating for dust and water resistance, operates within an extensive temperature range of -40°C to +65°C, and offers a signal output of 4-20 mA that auto-senses whether to sink or source.
Honeywell / Searchpoint Optima Plus
The 2108N4100H gas detector features a 3/4-inch NPT threaded spigot for easy installation. It operates effectively within a temperature range of -40 to 65 degrees Celsius for both storage and operational conditions. The device supports HART communication with a 4 to 20 mA output, and it includes adv
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / 301EM Series
This refrigerant gas sensor supports a voltage rating from 8.5 to 12.5 Vdc and operates with a maximum current of 1 A at 10 Vdc. It features an accuracy of ±10 ppm at low concentrations and ±40 ppm at higher levels. The operational environment accommodates temperatures between 0°C and 40°C with a hu
Honeywell / XNX Universal Transmitters
This gas transmitter weighs 5 lbs and features a robust housing made of painted marine-grade aluminum. It operates with a voltage range of 16 to 32 Vdc, consuming 6.5 watts of power. It can function optimally in temperatures from -40°C to 65°C, depending on the sensor used, and supports humidity lev
Honeywell / Sensepoint XCD
This transmitter features a 4-20 mA current output that can operate in either sink or source configurations. The kit includes a 705 catalytic bead combustible sensor, with a detection range of 0-100% LEL. It supports a maximum remote sensor distance of up to 30 m and can function within an operating