Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This circular chart recorder includes a 12-inch diameter chart and accommodates multiple input types: T/C, RTD, Radiamatic, as well as mV, 0–5V, and 4–20mA. It supports mounting via panel, 2-inch pipe, or surface methods and functions in relative humidity conditions of 5% to 90% (non-condensing). It
Honeywell / DR4500
This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with
Honeywell / SmartLine
Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp
Honeywell / UDA2182
This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display
Honeywell / HercuLine 2000
This actuator operates on a single-phase power supply of 100-130 VAC and has an input frequency of 60 Hz. It features a 3-wire drive for analog input operation and provides dual analog output signals at 1000 Ohms over its full rotation. The actuator rotates counterclockwise when the signal increases
Honeywell / UDC3500
This digital controller supports a wide range of inputs including TC, RTD, mV, as well as voltage and current signals. It operates with relay outputs configured as three Form C E-M Relays with a rating of 5 Amps each. Designed for a single control loop, it features a power compatibility that spans f
Honeywell / HercuLine 2000
This actuator operates on an input frequency of 60 Hz and requires a single-phase power supply of 100-130 VAC. It weighs 25 lbs and does not include advanced electronic components in its motor selection. The unit features dual 1000-ohm analog output signals while utilizing a 3-wire drive for up/down
Honeywell / SmartLine
Featuring an update time of 125 mSec, this transmitter operates effectively in environments with ambient temperatures from -40 °C to 85 °C. The IP66/IP67 rating indicates strong protection against dust and water, making it suitable for harsh conditions. It uses a basic alphanumeric LCD for display a