966 results
Honeywell / 7800 Series
This integrated burner control unit features a minimum operating temperature of -40°C and can withstand temperatures up to 60°C. It establishes a main flame in a maximum of 10 seconds, while the pilot flame requires either 4 or 10 seconds. The unit includes lockout interlocks for safety.
Honeywell / 7800 Series
This diagnostic tool is compatible with a range of relay modules, including RM7800, RM7840, RM7838, RM7888, RM7890, RM7895, RM7896, RM7897, and RM7898. The tester's primary function is to simulate control functions and interlocks for effective sequence testing of 2000 Series devices. It employs inte
Honeywell / 7800 Series
This device is designed for mounting as a plug-in module on Q7800A/Q7800B wiring subbases. It supports interrupted pilot types and has a main flame establishment duration of 10 seconds and a postpurge timing of 15 seconds. The operational temperature range extends from -40°C to a maximum of 60°C, ac
Honeywell / 7800 Series
This control module is capable of operating within a temperature spectrum from -40°C to 60°C. It also maintains functionality in humidity levels up to 85% relative humidity without condensation. The design includes a postpurge timing of 15 seconds and requires a 15A fast blow fuse for safety. The mo
Honeywell / 7800 Series
This burner control unit is rated for operation between temperatures of -40°C and 60°C and can be stored safely from -40°C to 66°C. It supports a maximum humidity range of 85% RH, non-condensing, and allows a total connected load of up to 2000 VA. The device features an initial pilot flame establish
Honeywell / 7800 Series
This microprocessor-controlled module is lightweight at 3 lbs and features a remarkable operating temperature range from -40°C to 60°C. It also offers storage conditions from -40°C to 66°C. The device maintains functionality in humidity levels up to 85% RH (non-condensing) and supports a maximum pow
Honeywell / 7800 Series
This rectification flame signal amplifier is available in a green color code, with a flame failure response time of either 2 or 3 seconds. It provides an output voltage of 0 to 5.0V DC and is capable of resisting vibrations up to 0.5 G. The device can function at temperatures ranging from -40°C to 6
Honeywell / 7800 Series
This flame signal amplifier supports a wide output range of 0 to 5.0V DC and features a dynamic self-checking capability. The device operates effectively within temperature limits of -40°C to 60°C, with a storage temperature range of -40°C to 65°C. Its design includes a green enclosure and offers a
Honeywell / 7800 Series
This relay control module features non-volatile memory, allowing for data retention without power. The device can withstand a minimum operating temperature of -40°C, functioning efficiently up to 60°C. It also has a vibration rating of 0.5 G and supports operation in conditions with relative humidit
Honeywell / 7800 Series
This relay control module features an intermittent pilot type and requires 4 to 10 seconds for pilot flame establishment. It includes dynamic checking for airflow switch validation. Its operation is supported across a temperature range of -40°C to 60°C and can be stored between -40°C and 66°C.