966 results
Honeywell / Searchpoint Optima Plus
This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio
Honeywell / Searchpoint Optima Plus
With a measurement range extending from 0 to 1000 ppm and a resolution of 1 ppm, this sensor provides detailed detection capability. It is built to operate efficiently within a temperature range of 0°C to 40°C and can function in humidity levels of 0-95% RH without condensation. This unit can be ins
Honeywell / Sensepoint XCD
The SPXCDULNO1M operates with a voltage range of 16-32 VDC and is rated IP66 for dust and water resistance. This detector can monitor oxygen levels from 0-25% volume, utilizing electrochemical sensing technology (Surecell). It includes three relays for alarm and fault signals, and provides output si
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / XNX Universal Transmitters
This gas transmitter weighs 5 lbs and features a robust housing made of painted marine-grade aluminum. It operates with a voltage range of 16 to 32 Vdc, consuming 6.5 watts of power. It can function optimally in temperatures from -40°C to 65°C, depending on the sensor used, and supports humidity lev
Honeywell / 301EM Series
Designed for reliable operation, this gas detection expansion module operates with an input voltage frequency of 50/60 Hz. It weighs 2.26 lbs and has a current rating of 2 A at 29 Vdc. The device operates efficiently within a temperature range of 0°C to 40°C and can function in humidity levels from
Honeywell / Sensepoint XCD
This transmitter features a 4-20 mA current output that can operate in either sink or source configurations. The kit includes a 705 catalytic bead combustible sensor, with a detection range of 0-100% LEL. It supports a maximum remote sensor distance of up to 30 m and can function within an operating
Honeywell / XNX Universal Transmitters
This gas detector operates efficiently within an extensive temperature range, from -40°C to 65°C. It can withstand storage temperatures from -40°C to 75°C and supports humidity levels of 0-99% RH, non-condensing. The housing is made of painted marine-grade LM25 aluminum alloy, ensuring durability in
Honeywell / Sensepoint XCD
This unit is rated IP66, allowing it to function effectively in harsh environments. The device operates within a temperature range of -40°C to 65°C and has a housing made of epoxy-painted LM25 aluminum alloy, ensuring durability. A maximum inrush current is specified at 800 mA at 24 VDC, with a 4-20