966 results
Honeywell / V5011
This threaded globe valve measures 1-1/2 inches and supports a flow capacity of 29.3 Cv with linear flow characteristics. It operates effectively with a steam pressure rating of 100 Psi and provides a water temperature range of 2°C to 120°C. The valve's action closes by moving the stem downward and
Honeywell / VGF Series
This flanged globe valve features a nominal size of 2-1/2 inches and is rated for a maximum pressure of 175 psi. It has a flow capacity of 63 Cv with a linear flow characteristic. The valve operates with a stem-down-to-close action and has a stroke size of 3/4 inches. It can handle media temperature
Honeywell / MP953
This pneumatic coil valve actuator operates effectively under an air connection system featuring a barbed fitting designed for 5/32 inches. It can maintain an operating pressure of up to 25 psi, with a stroke size of 3/4 inches. The actuator delivers a medium force and operates efficiently within a
Honeywell / 3G SmartVFD
This keypad/interface cable kit has a length of 3 meters and weighs 0.50 lbs. It is designed for compatibility with Honeywell SmartVFD HVAC and 3G SmartVFD Series drives. The cable supports NEMA 1, NEMA 12, and NEMA 3R enclosures, and operates effectively within a temperature range of -10°C to 50°C.
Honeywell / 7800 Series
This burner control functions within a voltage range of 120 VAC and is suitable for frequencies between 50 Hz and 60 Hz. It features a pilot flame establishing period of 3 seconds and a main flame establishing period that can be either 6 or 7 seconds. The control unit can operate in temperatures ran
Honeywell / 7800 Series
This programming burner control features a pilot flame establishment time of either 3 or 5 seconds, ensuring quick ignition. It also allows for a main flame establishing period that matches this timing. The unit supports a temperature operating range of -40 °C to 60 °C and can be stored from -40 °C
Honeywell / 7800 Series
This model features a main flame establishing period adjustable to 10, 15, or 30 seconds, and can also operate intermittently. It withstands temperatures from -40°C to 60°C during operation and has a storage temperature range of -40°C to 66°C. This burner control unit can handle a maximum connected
Honeywell / 7800 Series
This module is built to endure extreme temperatures, functioning between -40°C and 60°C, while also remaining effective in storage conditions from -40°C to 66°C. It features a notable humidity tolerance of 85% RH without condensation, and it can handle a maximum connected load of 2000 VA. It mounts
Honeywell / 7800 Series
This diagnostic tool is compatible with a range of relay modules, including RM7800, RM7840, RM7838, RM7888, RM7890, RM7895, RM7896, RM7897, and RM7898. The tester's primary function is to simulate control functions and interlocks for effective sequence testing of 2000 Series devices. It employs inte
Honeywell / 7800 Series
This device is designed for mounting as a plug-in module on Q7800A/Q7800B wiring subbases. It supports interrupted pilot types and has a main flame establishment duration of 10 seconds and a postpurge timing of 15 seconds. The operational temperature range extends from -40°C to a maximum of 60°C, ac