Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

969 results

969 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

LP920A1039

LP920A1039

Honeywell / Other

This controller operates on a dual-pipe system and functions effectively with a liquid-filled remote bulb sensing element. With a maximum sensing element temperature of 110°C and a controller temperature limit of 66°C, it ensures reliable performance. The capillary length extends to 5 feet, facilita

In Stock Ships Tomorrow
HP970B1015

HP970B1015

Honeywell / Other

Operating with two pipes, this humidistat features a throttling range from 3 to 15% RH. It consumes airflow at a rate of 0.011 scfm and maintains functionality under an operating pressure of 25 Psi. Its design allows it to work effectively across a temperature spectrum of 7 °C to 52 °C for operation

In Stock Ships Tomorrow
S7800A1142

S7800A1142

Honeywell / Other

This module features a two-row by twenty-column vacuum fluorescent display (VFD) and utilizes the Modbus communication protocol. Designed for robust performance, it can handle power dissipation up to 7 watts and a maximum power consumption of 2 VA. Operating temperatures range from -40 °C to 60 °C,

In Stock Ships Tomorrow
KS84230041

KS84230041

Honeywell / Other

This ionization pilot burner supports a max gas inlet pressure of 20-45 mbar and an air inlet pressure of 30-70 mbar. It produces a flame approximately 4 cm long and utilizes a direct spark ignition system with a 5kV ignition transformer. The flame is controlled through a single-electrode ionization

In Stock Ships Tomorrow
060-6951-01

060-6951-01

Honeywell / Other

The pressure transducer functions accurately within a temperature range of 0 to 40 degrees Celsius for operation and can be stored between 0 and 50 degrees Celsius. It can handle relative humidity levels of up to 80% and is designed for a clean indoor environment without corrosive agents. Installati

Call
DR45AH-1100-10-100-0-SA0000-0

DR45AH-1100-10-100-0-SA0000-0

Honeywell / DR4500

This circular chart recorder supports input through 1 and 2 channels, including T/C, RTD, and other sensor types. It provides an auxiliary output of 4-20 mA and has control output capabilities. The model is equipped with a NEMA 4x enclosure and is mounted using panel, 2-inch pipe, or surface methods

Call
DR45A1-1000-10-001-A-3A0000-0

DR45A1-1000-10-001-A-3A0000-0

Honeywell / DR4500

With a weight of 13.2 lbs, the recorder provides reliable control output and features two alarm outputs and two digital inputs. It operates effectively in temperatures ranging from 0 °C to 55 °C and can be mounted using panel, 2-inch pipe, or surface methods. Additionally, a keyed latch ensures secu

Call
DR45AT-1100-40-101-0-000000-0

DR45AT-1100-40-101-0-000000-0

Honeywell / DR4500

This circular chart recorder supports two input channels accepting T/C, RTD, Radiamatic, mV, and both 0–5V as well as 4–20mA signals. It includes a control output with SP programming, two alarm outputs, and two digital inputs. The device operates effectively within a temperature range of 0 °C to 55

Call
TVEZGR-61-600-11-0-000-000000-000

TVEZGR-61-600-11-0-000-000000-000

Honeywell / GR Series

This recorder features six primary analog inputs and supports an additional six through optional expansion cards. Its NEMA 3 enclosure offers protection against dust and water, and it operates effectively within a temperature range of 0 °C to 50 °C. The power requirement is 90-240V AC with a frequen

Call
TVEZGR-61-010-22-4-000-000000-000

TVEZGR-61-010-22-4-000-000000-000

Honeywell / GR Series

This advanced graphic recorder operates within an input frequency of 60 Hz and supports a power rating from 90 to 240 volts AC. It includes a substantial 2 GB of internal memory coupled with an 8 GB SD card for extensive data storage. Designed for standard panel mounting, it functions within a tempe

Call
Showing 571-580 of 969 results