Honeywell / Other
This detector is rated for an electrical input of 120/230 VAC, operating at frequencies of 50/60 Hz. With an impressive ambient temperature range from -40°C to 79°C, it is versatile in application. The device features a self-check function that utilizes an oscillating shutter to test the sensor tube
Honeywell / Other
This solenoid gas valve is suited for a pipe size of 2 inches and is made with a die-cast aluminum body for durability. The maximum operating pressure is rated at 5 psi (350 mbar). It has a quick response time with both opening and closing under one second. Temperature ranges from -40 °C to 63 °C ar
Honeywell / Other
This ionization pilot burner supports a max gas inlet pressure of 20-45 mbar and an air inlet pressure of 30-70 mbar. It produces a flame approximately 4 cm long and utilizes a direct spark ignition system with a 5kV ignition transformer. The flame is controlled through a single-electrode ionization
Honeywell / Other
The pressure transducer functions accurately within a temperature range of 0 to 40 degrees Celsius for operation and can be stored between 0 and 50 degrees Celsius. It can handle relative humidity levels of up to 80% and is designed for a clean indoor environment without corrosive agents. Installati
Honeywell / DR4500
This circular chart recorder supports input through 1 and 2 channels, including T/C, RTD, and other sensor types. It provides an auxiliary output of 4-20 mA and has control output capabilities. The model is equipped with a NEMA 4x enclosure and is mounted using panel, 2-inch pipe, or surface methods
Honeywell / DR4500
With a weight of 13.2 lbs, the recorder provides reliable control output and features two alarm outputs and two digital inputs. It operates effectively in temperatures ranging from 0 °C to 55 °C and can be mounted using panel, 2-inch pipe, or surface methods. Additionally, a keyed latch ensures secu
Honeywell / DR4500
This circular chart recorder supports two input channels accepting T/C, RTD, Radiamatic, mV, and both 0–5V as well as 4–20mA signals. It includes a control output with SP programming, two alarm outputs, and two digital inputs. The device operates effectively within a temperature range of 0 °C to 55
Honeywell / GR Series
This recorder features six primary analog inputs and supports an additional six through optional expansion cards. Its NEMA 3 enclosure offers protection against dust and water, and it operates effectively within a temperature range of 0 °C to 50 °C. The power requirement is 90-240V AC with a frequen
Honeywell / GR Series
This advanced graphic recorder operates within an input frequency of 60 Hz and supports a power rating from 90 to 240 volts AC. It includes a substantial 2 GB of internal memory coupled with an 8 GB SD card for extensive data storage. Designed for standard panel mounting, it functions within a tempe
Honeywell / DR4500
This standard chart recorder supports input from T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA, facilitating a broad range of measurements. It includes a single control output with SP programming capabilities. The unit operates effectively in temperatures from 0 °C to 55 °C and features a door with a g