753 results
Honeywell / Model 41 Series
This load cell features two diaphragms and outputs in both standard mV and voltage formats (4 to 20 mA and 0-5V DC, respectively). It offers accuracy at 0.10% and has infinite resolution, ensuring precise readings. The nominal bridge resistance is set at 350 Ohms, while operation can handle temperat
Honeywell / Searchpoint Optima Plus
Designed for various industrial applications, this flame detector features a detection field of 90°, making it effective at capturing flames from several angles. It utilizes a multi-spectral infrared sensing method, providing sensitivity to flames as small as 1 square foot from a distance of 30 feet
Honeywell / 301EM Series
This infrared gas detector efficiently measures hydrocarbons with a range of 0-100% LEL. It features an IP66/IP67 rating for dust and water resistance, operates within an extensive temperature range of -40°C to +65°C, and offers a signal output of 4-20 mA that auto-senses whether to sink or source.
Honeywell / Searchpoint Optima Plus
This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio
Honeywell / Searchpoint Optima Plus
With a measurement range extending from 0 to 1000 ppm and a resolution of 1 ppm, this sensor provides detailed detection capability. It is built to operate efficiently within a temperature range of 0°C to 40°C and can function in humidity levels of 0-95% RH without condensation. This unit can be ins
Honeywell / Sensepoint XCD
The SPXCDULNO1M operates with a voltage range of 16-32 VDC and is rated IP66 for dust and water resistance. This detector can monitor oxygen levels from 0-25% volume, utilizing electrochemical sensing technology (Surecell). It includes three relays for alarm and fault signals, and provides output si
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / 301EM Series
Designed for reliable operation, this gas detection expansion module operates with an input voltage frequency of 50/60 Hz. It weighs 2.26 lbs and has a current rating of 2 A at 29 Vdc. The device operates efficiently within a temperature range of 0°C to 40°C and can function in humidity levels from
Honeywell / Sensepoint XCD
The SPXCDULNFX flammable gas detector features an IP66 rating and can function within a temperature span of -40°C to 65°C. The device supports a continuous humidity range of 20-90% RH and intermittent levels of 0-99% RH. It utilizes a catalytic bead sensor capable of detecting methane concentrations